Classification of AUMA actuators

The following table illustrates the figures for selected

AUMA actuators

Figure

AUMA 10-03-053

R006 V2R0

SA .2 AUMA NORM

AUMA 10-03-053

R006 V2R0

SA .2 AUMA NORM

with PVST

Safety function

OPEN/CLOSE

OPEN/CLOSE with PVST

safe

367 FIT

367 FIT

Ko

0 FIT

162 FIT

 

203 FIT

41 FIT

DCD

0 %

80 %

MTBF

201 a

201 a

SFF

64 %

92 %

"^"[proof] ^ ys3r

PFDAVG= 1.05 X 10 3

PFDAVG = 4.96x IO"4

T[Pr„„,] =2 vears

PFDAVG= 1.92 X 10 3

PFDAVG= 6.55 X IO"4

T[Pr„„,] =5 vears

PFDAVG = 4.53x10-3

PFDAVG= 1.13 X IO"3

SIL capability

SIL 2

SIL 2

Please contact us for further SIL figures of other actua-

tor types.

Improvement of SIL capability

Regular function tests, for actuators the so-called partía

valve stroke tests (PVST), and/or the use of actuators in

redundant configuration (1oo2) can reduce the failure

probability of a safety-related system and thus improve the

SIL capability to SIL 3.