| | [Ï0| DIGITAL INTEGRAL DRIVERS -TES - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS | |
| | | |
| | MAIN CONNECTOR 7 PIN - STANDARD | | |
| | | |
| | 12 PIN - OPTION /Z, /SP, /SF and /SL | |
| | | |
| | REMOTE PRESSURE (FORCE) TRANDUCER (for /SP, /SF and /SL) | |
| | | |
| | 10.1 ELECTRONIC CONNECTIONS - 7 & 12 PIN MAIN CONNECTORS | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | Power supply 24 Vdc for solenoid power stage (and for driver logic on 7 pin connection) | | | | | | | | Power supply 0 Vdc for solenoid power stage (and for driver logic on 7 pin connection) | | | | | | | | Enable (24 Vdc) or disable (0 Vdc) the driver | | | | | | | | Reference analog input: ±10 Vdc maximum range (4 - 20 mA for /I option) standard: differential input; /Z option: common mode INPUT+ referred to AGND | | | | | | | | | | | | | | Ground - signal zero for MONITOR signal signal zero for INPUT+ signal ( only for /Z option) | | | | | | | | Monitor analog output: ±10 Vdc maximum range (4 - 20 mA for /I option) | | | | | | | | do not connect ( pressure/force input for /SP, /SF and /SL options, see 7.3 ) | | | | | | | | do not connect ( pressure/force monitor for /SP, /SF and /SL options, see 7.3 ) | | | | | | | | Power supply 24 Vdc for driver logic | | | | | | | | Power supply 0 Vdc for driver logic | | | | | | | | Fault (0V) or normal working (24V) | | | | | | | | Internally connected to the driver housing | | | | | | | | | | | | |
| | | |
| | Note: A minimum time of 300 to 500 ms have be considered between the driver energizing with the 24 VDC power supply and when the valve Is ready to operate. During this time the current to the valve coils is switched to zero. | |
| | | |
| | 10.2 ELECTRONIC CONNECTIONS - 5 PIN COMMUNICATION CONNECTORS | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | data line and termination Signal zero | | | | | | Valves receiving data line | | | | | | | | | | Valves transmitting data line | | | | | | | | | | | | | | | | |
| | | |
| | |111 SOFTWARE TOOLS The functional parameters of the digital valves, as the bias, scale, ramp and linearization of the regulation characteristic, can be easily set and optimized with graphic interface by using the Atos E-SW software and the relevant USB adapters, cable and terminators, see tab. G500. Valves with fieldbus communication interface (-BC and -BP) can be completely managed by the machine control unit; it is required to implement in the machine control the standard communication as described in the user manuals supplied with the relevant programming software. For detailed description of availabile fieldbus features, see tab. G510 | |
| | | |
| | 12 MAIN CHARACTERISTICS OF PROPORTIONAL DIRECTIONAL VALVES | |
| | | |
| | | | | | | | | | | | | | | Subplate surface finishing | Roughness index, ^ flatness ratio 0,01/100 (ISO 1101) | | | | | -20°C - +70°C for -T execution; -20°C - +60°C for -TE and TES executions | | | | | Hydraulic oil as per DIN 51524 ... 535 for other fluids see section CD | | | | | 15 -100 mm2/s at 40°C (ISO VG 15-100) | | | | Fluid contamination class | ISO 18/15 achieved with in line filters of 10 urn and (S10 >75 (recommended) | | | | | -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals) | | | | | | | | | | Coil resistance R at 20°C | | | | | | | | | | | | | | | | | | | H (180°) Due to the occuring surface temperatures of the solenoid coils, the European standards ISO 13732-1 and EN982 must be taken into account | | | | Protection degree (CEI EN-60529) | IP65 for -T execution; IP65-67 for -TE and -TES executions, depending to the connector type (see sect. frj H ) | | | | | Continuous rating (ED=100%) | | | | | | | | | |
| | | |
| | | | |