|
catalogue search
|
You may also be interested in
Test chamber, Weather station, Concentrator, Corrosion chamber
Text version of the page
Accelerated Weathering ProductsNOW Catalog - 27780 SUNTEST®/UV2000Comparison ChartSUNTEST XXL/XXL+ SUNTEST XLS/XLS+ SUNTEST CPS/CPS+ UV2000 Light SourceMinimum Guaranteed Lamp Life3 x 2100 W Air-Cooled Xenon Arc Lamp 1500 HoursAuxiliary Filter System 1700 W Air-Cooled Xenon Arc Lamp 1500 HoursAuxiliary Filter System 1500 W Air-Cooled Xenon Arc Lamp 1500 HoursAuxiliary Filter System 8 x 40 W Fluorescent Lamps N/A N/A Automatic control at 320 nm or 340 nm 4 Smart Light (at one sun level)Filters Irradiance Control Light MonitorHumidity Control (RH) Humidity Range Temperature ControlBlack Panel or Black Standard Temperature RangeSimultaneous Control of BPT or BST and Chamber TemperatureDual BPT/BST Control Specimen Rack TypeTotal Exposure Area Specimen Holders Electric HVAC - MJ/h (BTU/h) (Max.) Compressed AirPressureHumidificationSpecimen SprayRack SprayPhysical Dimension (WxDxH) FootprintFloor WeightStandardsDeionized Water Flowrate(see page 10 for a complete list) (see page 10 for a complete list) (see page 10 for a complete list) Auotmatic at 340 nm, 420 nm or 300-400 nm Built-in SUNSENSIV sensorsAutomaticLight Cycle*: 40-80% Dark Cycle: Up to 95% Up to 70° CBPT 45-90 C BST 45-100° C StandardN/AFlatbed3000 cm Automatic control at 300-800 nm, 300-800 nm, or LUX Built-in SUNSENSIV sensorsN/A N/A N/A BST 45-100° CN/A Automatic control at 300-800 nm CPS+: built-in SUNSENSIV sensorsN/A N/A N/A BST 35-100° CN/A™ MonitorsN/A N/A Automatic ±2° C BPT 30-90° C N/AN/A2 "near" vertical exposure areas5175 cm *Light cycle values are measured under 100% burner intensity and 2000 RPM ( Monitoring of chamber temperature only) (CPS+: Monitoring of chamber temperature only) N/AFlatbed1100 cm N/AFlatbed560 cm 2 (478 in 2 ) See Page 35400 V± 10%, 50/60 Hz; 200-400 V 50/60 Hz 3 Phase/3 Wire 2 (171 in 2 ) N/A200-240 V, 50/60 Hz (1, N, PE); CEE (32 A, 3 pole 6h) 11.160 MJ/h (10578 BTU/h) N/AN/AN/A 2 (86 in 2 ) N/A200-240 V, 50/60 Hz (1, N, PE); CEE (16 A, 3 pole 6h) 7.561 MJ/h (7166 BTU/h) N/AN/AN/AOptional ImmersionN/A78 cm x 35 cm x 35 cm 100 cm x 95 cm 29 kg (64 lb) 2 (828 in 2 )(23) 7.5 cm x 30 cm; or (15) 10 cm x 30 cm120 V, 1 Phase, 50/60 Hz, 12 A; or 230 V, 1 Phase, 50/60 Hz, 8 A N/A N/A193 kPa (28 psi)N/A7.2 l/minN/A135 cm x 51 cm x 155 cm 135 cm x 51 cm 129 kg (285 lb) Other voltages available upon request 35.0 MJ/h (33175 BTU/h) N/AN/AXXL+: 4 l/h max.XXL+: 0.31 l/minN/A90 cm x 91 cm x 172 cm 335 cm x 315 cmXXL: 280 kg (615 lb) XXL+: 290 kg (638 lb) Optional Specimen Spray & Immersion N/A90 cm x 54 cm x 62 cm 150 cm x 170 cm 90 kg (176 lb) AATCC TM16 TM169 ASTM D3424 D5071 D6695 G151 G155 ASTM D3424 D5071 D6695 G151 G155 ASTM D4329 D4799 D4587 D5208 G154 G53 ASTM C1442 C1501 D6695 G151 G155 EPA/ ASTM COLIPA 2007A Guideline BS 2782 This is a sample of global standards that can be met by this instrument. For more information on additional or specific standards, contact your local Atlas representative. Standards are subject to change without notice. This might lead to the inclusion or exclusion of certain instruments. EPA/ASTM E896 E896 EPA/ ASTM ECCA T10 ISO 4049 7491 11341 4665 4892-1 4892-2 11431 11979-5 18909 ICH E896 EN 534 927-6 Guideline Q1B Q5C ICH ISO 11507 4892-3 ISO 11431 11979-5 7491 4049 4892-1 4892-2 10977 Guideline Q1B Q5C JIS D0205 ISO 11431 11979-5 7491 4049 4892-1 4892-2 10977 prEN 1062-4 SAE J2020 VW PV 1306 PV3929 PV 3930 31Phone: +1.773.327.4520 www.atlas-mts.com |