Accelerated Weathering Products

NOW Catalog - 27780 Ci Series

Comparison Chart

Ci5000 Weather-Ometer

®

Ci4000 Weather-Ometer Ci3000+ Weather-Ometer Ci3000+ Fade-Ometer

®

Light SourceMinimum Guaranteed Lamp Life

12000 W Water-Cooled Xenon Arc Lamp 1200 HoursInterchangeable Inner and Outer 6500 W Water-Cooled Xenon Arc Lamp 1200 HoursInterchangeable Inner and Outer 4500 W Water-Cooled Xenon Arc Lamp 1200 HoursInterchangeable Inner and Outer 4500 W Water-Cooled Xenon Arc Lamp 1200 HoursInterchangeable Inner and Outer (at one sun level)

Filters Irradiance Control Light MonitorHumidity Control (RH) Humidity Range Temperature ControlBlack Panel or Black Standard Temperature RangeSimultaneous Control of BPT or BST and Chamber TemperatureDual BPT/BST Control Specimen Rack TypeTotal Exposure Area Specimen Holders Electric HVAC - MJ/h (BTU/h) (Max.) Compressed AirPressureHumidificationSpecimen SprayRack SprayPhysical Dimension (WxDxH) FootprintFloor Weight (without skid)StandardsDeionized Water Flowrate

(see page 8 for a complete list) (see page 8 for a complete list) (see page 8 for a complete list) (see page 8 for a complete list) Automatic single point control at 340 nm or 420 nm or 300-400 nm; optional monitoring at 2nd pointSmart Light Automatic single point control at 340 nm or 420 nm or 300-400 nm; optional monitoring at 2nd pointSmart Light Automatic single point control at 340 nm or 420 nm or 300-400 nm; optional monitoring at 2nd pointSmart Light Automatic single point control at 340 nm or 420 nm or 300-400 nm; optional monitoring at 2nd pointSmart Light
™ MonitorAutomaticLight Cycle: 10-75% (Dependent on Temp) Dark Cycle: Up to 100%Automatic BPT 40-110° C; BST 40-120° C StandardOptional3 Tier11000 cm
™ MonitorAutomaticLight Cycle: 10-75% (Dependent on Temp) Dark Cycle: Up to 100%AutomaticBPT 40-110° C; BST 40-120° C StandardOptional3 Tier6500 cm
™ MonitorAutomaticLight Cycle: 10-75% (Dependent on Temp) Dark Cycle: Up to 100%AutomaticBPT 40-110° C; BST 40-120° C StandardOptionalSingle Tier2188 cm
™ MonitorAutomatic Light Cycle: 10-75% (Dependent on Temp)AutomaticBPT 40-110° C; BST 40-120° C StandardOptionalSingle Tier2188 cm
2 (1705 in
2 ) See Pages 33-34400/480 V, 3 Phase, 3 Wire, 50/60 Hz, 60 A; or 400 V, 3 Phase, 50 Hz, 65 A 64.22 MJ/h (60870 BTU/h, 800 CFM)0.11 m
2 (1008 in
2 ) See Pages 33-34200/250 V, 3 Phase, 3 Wire, 50/60 Hz, 52 A; or 200/250 V, 3 Phase, 4 Wire, 50 Hz, 42 A 41.36 MJ/h (39203 BTU/h, 450 CFM)0.11 m
2 (339 in
2 ) See Pages 33-34200/250 V, 1 or 3 Phase, 50/60 Hz, 47/57 A; or 400/230 V, 3 Phase, 4 Wire, 50 Hz, 38 A26.06 MJ/h (24703 BTU/h, 275 CFM)0.11 m
2 (339 in
2 ) See Pages 33-34200/250 V, 1 or 3 Phase, 50/60 Hz, 47/57 A; or 400/230 V, 3 Phase, 4 Wire, 50 Hz, 38 A26.06 MJ/h (24703 BTU/h, 275 CFM)0.11 m
3 /min (4 CFM max.) @ 552 kPa (80 psi)124-207 kPa (18-30 PSI)0.2 l/min 0.2 l/min 0.2 l/min160 cm x 130 cm x 198 cm212 cm x 293 cm including access area807 kg (1780 lb)
3 /min (4 CFM max.) @ 552 kPa (80 psi)124-207 kPa (18-30 PSI)0.2 l/min 0.2 l/min 0.2 l/min127 cm x 102 cm x 198 cm180 cm x 272 cm including access area585 kg (1290 lb)
3 /min (4 CFM max.) @ 552 kPa (80 psi)124-207 kPa (18-30 PSI)0.12 l/min 0.07 l/min 0.07 l/min97 cm x 84 cm x 183 cm146 cm x 256 cm including access area410 kg (905 lb)
3 /min (4 CFM max.) @ 552 kPa (80 psi)124-207 kPa (18-30 PSI)0.12 l/minN/A N/A97 cm x 84 cm x 183 cm146 cm x 256 cm including access area410 kg (905 lb) AATCC TM 16-2003 AATCC TM 16-2003 AATCC TM 16-2003 AATCC TM 16-2003 TM 16E-1998 TM 16E-1998 TM 169 TM 16E-1998 TM 169 TM 16E-1998 TM 169 ASTM G151 G155 D6695 D2565 E1596 ASTM G151 G155 D6695 D2565 E1596 ASTM G151 G155 D6695 D2565 E1596 ASTM G151 G155 D6695 D2565 E1596
This is a sample of global standards that can be met by this instrument. For more information on additional or specific standards, contact your local Atlas representative. Standards are subject to change without notice. This might lead to the inclusion or exclusion of certain instruments. Ford FLTM BO 116-01 Ford FLTM BO 116-01 GME 60292 GME 60292 GME 60292 GME 60292 ISO 105-B02 105-B04 105-B06 11341 3917 4892-1 4892-2 12040 ISO 105-B02 105-B06 12040 GMW 3414TM 14162 GMW 3414TM 14162 ISO 105-B02 105-B04 105-B06 11341 3917 4892-1 4892-2 12040 ISO 105-B02 105-B04 105-B06 11341 3917 4892-1 4892-2 12040 JASO M 346 Marks &Spencer JASO M 346 C9 C9A Marks &Spencer Renault D47 1431 JASO M 346 JASO M 346 C9 C9A VDA 75202 MIL STD 810 G MIL STD 810 G MIL STD 810 G VW PV 1303 PV 3929 SAE J1885 J1960 J2412 J2527 SAE J1885 J1960 J2412 J2527 SAE J2412 J2527 VDA 75202 VDA 621-429 621-430 75202 VDA 621-429 621-430 75202 VW PV 1303 PV 3929 PV 3930 VW PV 1303 PV 3929 PV 3930 VW PV 1303 PV 3929 PV 3930

29

Phone: +1.773.327.4520 www.atlas-mts.com

pageCatalog pdf di En 2012-02-07-16