| | | | | | | | | | | | | | ^^^^1^ Accelerated Weathering Products ^'.ï | | | | Features | SC340 | SC600 | SC1000 | SC2000 | | | | MH Wattage | 1 x 1500 | 1 x 1500 | 2 x 1500 | 4 x 1500 | | | | MHG Wattage | 1 x 1200 | 1 x 2500 | 1 x 2500 | 2 x 4000 | | | | Exposure Area (cm2) | 1,600 | 3,000 | 5,600 | 13,600 | | | | Temperature chamber volume (l) | 340 | 600 | 1000 | 3400 | | | | Spectral distribution according to CIE No. 85 Table 4 (base) and DIN 75220, Table 1, Column 2/4 (shares) • | • | • | • | | | | Easy-to-use touch screen | • | • | • | • | | | | Climate with/without irradiation | • | • | • | • | | | | Control and display of irradiance, chamber temperature, humidity and dew point | • | • | • | • | | | | Programmable heat-up and cool down speed | • | • | • | • | | | | Swiveling operator panel | • | • | • | N/A | | | | Operator Panel integrated into control module on front side N/A | N/A | N/A • | | | | Microprocessor control | • | • | • | • | | | | CE compliant | • | • | • | • | | | | Insulated cover to expand temperature range | | | | ■ | | | | Misting equipment to expand climate possibilities | ■ | ■ | ■ | ■ | | | | UV sensors: 280-320 nm / 320-400 nm | | | | ■ | | | | Control of Black Standard Temperature | ■ | ■ | ■ | ■ | | | | Black Standard Thermometer | | | | ■ | | | | Solar test sensor: 300-3000 nm | ■ | ■ | ■ | ■ | | | | RS422/485 interface | | | | ■ | | | | Printer: 6-color, programmable | ■ | ■ | ■ | ■ | | | | SMPATI™ software for data acquisition | | | | ■ | | | | | | | | | | | | |
| | | Accelerated Weathering Products | | |
| | | |
| | | Solar Simulation Chambers Simulating Indoor and Outdoor Conditions for Whole Components and Finished Products The SC series is equipped with either MH (Metal Halide) or MHG (Metal Halide Global) lamps to achieve an accelerated simulation of indoor and outdoor weathering. The MHG lamp has the ability to vary output across a specific range and does not exhibit the energy peaks at certain wavelengths, which are found in the MH spectrum. These peaks can produce widely differing results in samples with corresponding spectral sensitivity. MH units are therefore preferred for heat load tests. All SC units are suitable for laboratory testing using simulated sunlight and the MHG models are the best solution for aging tests. The SC340, SC600, SC1000 and the SC2000 can be used as full-function climate chambers. Solar Climatic Features and Benefits ■ Spacious test chamber design offers four test capacities allowing testing of components with large surface areas (for example airbags) or even complete large components (for example instrument panels, bumpers, side panels, etc.) ■ Influencing parameters such as global irradiation, temperature, and humidity can be individually programmed ■ Easily accessible communications and control units guarantee ease of use for the operator | | |
| | | |
| | | ■ High performance program functions allow the design of very flexible test specifications to match the customer's individual testing needs Standards The SC series meets or exceeds the following industry standards: | | |
| | | |
| | | • Standard | | ■ Optional | | |
| | | |
| | | |
| | | |
| | | Specific Utility Requirements and Specifications for each instrument can be found on page 32, SPD graphs on pages 11-12, Filter Combinations on page 9. | | |
| | | BMW DIN IEC ISO MIL STD VW | | PrV 306 75 220 68-2-5 9022-9 810 F PV 1211 | | |
| | | Common | |
| | | |
| | | |
| | | Temperature and Humidity Control | | |
| | | SC2000 | | |
| | | A | 97�714 | pplications: | | |
| | | |
| | | 12097-2 505.4 | | |
| | | |
| | | Automotive 3D Plastic Components Chemicals Electronics MilAero Photovoltaics Roofing Window Units | | |
| | | with irradiance — without irradiance | | |
| | | |
| | | 100 80 60 40 20 0 | | |
| | | |
| | | |
| | | |
| | | This is a sample of global standards that can be met by this instrument. For more information on additional or specific standards, contact your local Atlas representative. Standards are subject to change without notice. This might lead to the inclusion or exclusion of certain instruments. | | |
| | | SC600 | | |
| | | |
| | | |
| | | |
| | | 0 10 20 30 40 50 60 70 80 90 100 Test Chamber Temperature [°C] Operable ranges of humidity control at various test chamber temperatures (under normal laboratory conditions). | | |
| | | |
| | | „., Phone: + 1.7 7 3.3 27.45 20 27 www.atlas-mts.com | | | Phone: +1.773.327.4520 www.atlas-mts.com | | |
| | | 28 | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |