You may also be interested in
Hydrogen detector, Safety tester, Electrical tester, Leak tester, Milliohmmeter
Text version of the page
General details Measurement specificationTemperature range Operating -10Ëš to 50ËšC Function Range Accuracy (1) Power supply 110/240V,50 to 400 Hz AC, 150VA Altitude: -2,300 to 60,000ft ±3ft at 0ft Case: Completely weatherproof,meets ±8ft at 30,000ft EMC requirements - MIL STD 462D ±32ft at 60,000ft Physical: 515mm x 380mm x 270mm -700 to 18,000m ±1m at 0m 17 kg (38 lbs) ±2.5m at 9,000m Calibration: Recommended period 12 months ±10m at 18,000m Ease of Use Remote touch screen Altitude rate: Up to ±6,000ft/min ±1% Integrated bag for cables and ho- max.±2,000m/min ±1% Ease of maintenance: Maintenance limited to calibration, Indicated airspeed: 10 to 800kts ±2kt at 50kts regular external cleaning andPITOT STATIC TESTER - ADSE 743 - 7689 RVSM COMPLIANT±0.14kt at 500kts exchange of filters ±0.07kt at 800kts (with the calibration) 20 to 1480km/h ±3km/h at 100km/h ±0.26km/h at 900km/hOptional±0.13km/h at 1480km/Power supply : 17 to 32V DC Mach No: 0.1 to 4.0 Mach ±0.002M at 0,8M/25,000ft Remote Control Software for PC (Windows 2000 & XP) ±0.004M at Static sensor 30 to 1200 mbar 0,01% FS (1) Pitot sensor 30 to 3000 mbar 0,01% FS (1) (1) linearity + repeatability + hysteresis at ambiant +10° to +40°C x 1,5 for -10° to +50°C x 0,5 for ±2°C lab useATEQ-OMICRON - 8, route de Chevreuse - F78117 - Chateaufort - France - Tél : +33 (0)1 39 075 002– Fax : +33 (0)1 39 075 019 - e-mail : aero@omicron.ateq.com |
|