TL6

Battery and Fuel Cell Test Load

TL6 Test Load

SPECIFICATIONS X Current range Voltage compliance range Maximum power dissipation Reverse polarity protection Resistance free voltage sampling time delay Clock range Inputs Display Expansion I/O port - digital inputs - digital outputs - analog inputs Communication ports Instrument power Cooling Heat sink temperature Dimensions (L x W x H) 0 - 20.00 A 0 - 200.0 A 1.2 - 200 VDC 1000 W (internally limited) yes 0.1, 1 or 10 ms 0 - 99:59:59 hours with start/stop/clear + - power (Anderson series SB175) + sense, - sense, reference 3 temperature inputs: -40 to 125 ºC (type T sensor) LCD, 80 characters, 4 lines 25-pin D-connector Eight, HCMOS standard Eight, HCMOS standard 2 single ended inputs ± 2.047 V RS-485 115 V 50-60 Hz (standard) 230 V 50-60 Hz (optional) Forced air 75ºC max, over temperature protection 340 x 270 x 280 mm (13.3 x 10.5 x 11 in)

TL6 Battery and Fuel Cell Test Load

MODEL TL6 Intelligent Test Load for Batteries and Fuel Cells is a passive electronic load with built-in microprocessor intelligence, with ability to briefly interrupt the current and take resistance free potential readings with a programmable delay. There are additional inputs, for a reference and for up to three temperature sensors. An expansion I/0 connector provides further eight digital inputs, eight digital outputs and two analog inputs. Microprocessor controls the time keeping and data acquisition functions, and the measured values are displayed on an 80-character LCD display. Current ranges of 0 – 20.00 A and 0 – 200.0 A are operator selectable; voltage (potential) up to 200.0 V is autoranging. The instrument has the capability to operate under manual or remote control, and to communicate with a computer over a serial RS-485 link. Optional TLIF interface module and TESTMASTER™ software, sold separately, allows for connection, control and acquisition of data from TL6 and TL5 loads in a daisy chain configuration.

RELATED PRODUCTS

The TL6 Test Load has the capability to operate under manual or remote control, and to communicate with a computer over a serial RS-485 link. Optional TLIF interface module and TESTMASTER™ software, sold separately, allows for connection, control and acquisition of data from up to 16 TL5/TL6 loads in a single daisy chain configuration per available RS-485 port.

March 2006 - Note: ASTRIS ENERGI Inc. reserves the right to change this specification without notice.