| Characteristics | | SX series | SR40 series | Safety mats |
| Protection | Type 2 or 4 according to EN 614% | Type 4 according to EN 614% | Category 3 according to EN 954 |
| Ax | 40 mm sensibility | • | • | < 300 N on a surface of080mm < 600N on a surface of0200mm |
| 50 mm sensibility | • | |
| 90 mm sensibility | • | • |
| Maximal protected area (m) | 32m2( 1,81 x 18 m) | 108 nr ( LSI x 60 i | 4,5 m2 per mat |
| Maximal protected width (m) | 1810mm | 1810 mm | 3000 mm |
| Dimensions | | 35 x 45 mm | 50 x 60 mm | To be defined |
| Power supply | | 24 VDC +/- 20% | 24 VDC +/- 20% | 24 VDC - 230 VAC |
| Safety outputs | | Static | Static | Relay- |
| Safety functions | | Automatic restart Entrance test | Auto / manu restart EDM ' entrance lest | Auto / manu restart |
| Watertightness | | IP65 | IP65 | 1P65 (Mat) |
| Working temperature | | 0 à + 55°c | 0 a + 55°c | 0 a + 60°c |
| Fixing | | Brackets | Brackets | with / without brackets |
| Connecting | | MI2 | M12 | Cables or connectors |
| Output informations | | | | Yes |
| Display | | Visual display unit I ted | Visual display unit + led | Led |
| Main advantages | | No wearing elements. Immune to soldering dashes. MI2 connectors included. | No wearing elements. Immune to soldering flashes. | 1 ligh tolerance to wearing Brackcis included Maximal load: 4 T. 3 mai-covcring types: PVC. reintbrecd PVC . alu |
| Approvals | | flit irvi l;l | Ill IIVl II | CE(TUV) |
| Data shed | | 1.1 374 hi 375 | I- 1' 3X0 | ET409 |