Text version of the page
PRODIS
®
PD-INC
Digital process meter for incremental sensors
Value range display, offset, limit values-999999 to +999999Divisor, Multiplier0 to 999999Other programmable parametersCounting direction, decimal point position, last-value memory, Z signal evaluation, display brightnessSignal TManual zero, key lock, display value hold, Z release, relative measurement activation >
Programmable parameters / value range Wiring basic unit
SignalsConnector X1 pin no.Connector X2 pin no. Sensor +U >
B 1Sensor 0 V (GND)2Signal A4Signal A 5Signal B6Signal B 7Signal Z (zero signal)8Signal Z (zero signal)9Signal T (reference signal)10Signal T (reference signal)11GND12PD-INC-24VDC Excitation +24 V Excitation 0 V (GND) 13 14PD-INC-230VAC Excitation Protective ground 13, 15 14 >
1.....................................12 13 14 15X1X2X1X2
5 ........ 1RS-232
13 14 15 PD-INC-24VDCPD-INC-230VAC Rear view without comparator outputs
LevelRS-232: ±8 V, galvanically isolatedData format1 start bit, 8 data bits, 1 stop bit, no parityTransmission rate4800 / 9600 / ... / 115200 Baud >
RS-232 interface
SignalsConnector X3 Pin No.SUB-D Pin No. TxD172RxD163GND185 >
Rear view with comparator outputs and outline drawings see pages 48 and 49. ASM CAT-PR/PT-E-07 45 www.asm-sensor.com