Max. pulse frequency fp50 kHz, 20 kHz, 10 kHz (standard 50 kHz)Outputs A, A, B, B, reference pulse Z, Z, end position signal E, E, status signal ERRMaterial of enclosureZinc die castingElectrical connectionCable 8 wire, Ø 5 mm, open cable end,9 pin D-sub connector at the cable end as option.
Max. length of the integrated sensor cable for
TTL: 3 m; HTL/TTL24V: 20 mWeight (w/o cable and connector)30 ±5 gProtection class (EN 60529)IP67 >
Specifi cations (continued)
Environmental EMCDIN EN 61326
Temperature-20 ...+85°CThe subsequent counting device must be able to process the specifi ed maximum pulse frequency of the sensor. Saturation voltageUH, UL = 0,2 V I = ±10 mA (UH = UB - U )UH, UL = 0,4 V I >
Output signals
out out out = ±30 mAC >
last < 10 nFShort circuit currentISL, ISH < 800 mA (UH, UL = 0 V)ISL, ISH < 90 mA (UH, UL = 1,5 V)Rise timet >
r , t >
f < 200 ns with cable length 1 m, 10 % … 90 % Load/cable lengthLoad/pulse frequency fpHTL single ended >
Pulse frequency in dependence on the cable length
TTL/RS422 differential TTL/24 V UB = 24 V UB = 5 V * UB = 24 VMax. output current 50 mA50 mA10 mAR >
last min.500 Ω100 Ω500 ΩC >
last max.10 nF10 nF1 nF200 m15 kHz——
100 m 25 kHz100 kHz—50 m50 kHz200 kHz50 kHz10 m100 kHz300 kHz100 kHz* = consider the voltage loss of the cable; the excitation voltage 5 V ± 5% of the sensor must be guaranteed.Note: For longer distances (see specifi cation above) you must use min. 0,5 mm >
2 wire for „Excitation+“ and „Excitation GND“ (see signal wiring next page), all signal wires must be min. 0,14 mm >
2 ! >
Outline drawing
Active measurement rangeDimensions informative only. For guaran-teed dimensions consult factory. Reference markPosition tolerance of the active measurement range: dx = ±1 mm ASM GmbH CAT-PM-E-04 7 Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com >