Functional Specifications
Dimensions
Ranges: 40F to 199F, 0F to 250F40C to 120C >
PANEL MOUNTING HOLES, TYPICAL 2 PLCS,USE ANSI TYPE BT, NO. 4 THREAD CUTTING
SCREWS FOR PLASTIC.
SCREW LENGTH: PANEL THICKNESS +.375 ➤ 1.39 ➤ ➤ ➤ Over Range: Displays -1 >
➤ 1.625 ➤ F POWER AND SENSOR PLUG Under Range: Displays -1 >
0.750 2.03 ➤ Ambient TemperatureLimit: >
➤ ➤ 30F to +160F (34C to 71) >
➤ 1.600 ➤ ➤ 1.28 ➤ Temperature Stability: 0.01%/F >
2400E
2410E
➤ 1.750 ➤ POWER AND SENSORPLUG ➤ ➤ .875 ➤ .128(TYP) Storage Temperature: 40F to 180F >
➤ ZERO AND SPANADJUSTMENTS ➤ ➤ Zero and Span 10% of range through two single-turn >
➤ Adjustments:
potentiometers accessible through the back of the
industrial thermometers module >
.860.382 PANEL CUT OUT 1.625 ➤ ➤ ➤ Z S ➤ Power: 110 Vac input (220 or 24 Vac optional), 6 Vdc regulated output, 50/60 Hz, 300mA >
REVERSE SIDE ➤ Humidity Limits: Up to 100% RH at 140F >
➤➤ 1.230.146 ➤ ➤ ➤ 0.985 Approvals: U.L. recognized (file: E103515) NSF C-2CSA (file: Natl/c, LR76285-2) >
➤ ➤ ➤ F 2.302 HEX NUTS6 - 32UNC-2B THD
CAD PLATED STEEL2 STUDS6-32UNC-2A THD x .750 LONG 0.750 ➤ Physical Specifications
➤ ➤ Display: LED with >
1 ⁄ >
2 ˝ x >
1 ⁄ >
4 ˝ numerals >
➤ 1.600 ➤ PANEL CUT OUT: 2 3/32 DIA Sensor: Laser trimmed 2000 ohm RTD >
➤
➤ ➤ 1/16 TO 3/4 PANEL THK Sensor Dimensions: .250˝ Dia. x 2.54˝ Long, 300 series stainless steel with 8 wire cable >
➤ ➤ 2.220 Mounting: 2400 Flush mounted from back of panel using adhesive bonding, or #4 Type BT thread cutting screws. Screw length: 0.375 + panel thickness. 2˝ and 2 >
1.375 ➤ ➤ ➤ 1 ⁄ >
2 ˝ dia. flanges per ASME B40.1 are also available. >
Z S ➤ 2410 Panel mounted from back of panel using U-clamp included. Maximum panel thickness: 0.75˝ >
➤➤ 1.0 Weight: Display: 35 grams (0.08 lb) Power supply: 2.11 grams (.5 lb) >
2.03
POWER ANDSENSOR PLUG
ZERO AND SPANADJUSTMENTS ➤➤ Selection Table 2400EA08040/199 FXJ8CODE DESC.CODE DESC.CODE DESC.CODE DESC.CODE DESC.RANGE CODE TABLE 1TABLE 2TABLE 3TABLE 4TABLE 5TABLE 6 (1)
(2)(2) Performance Specifications
MODELDISPLAYPOWER SUPPLYLINE LENGTHOPTIONS FXJ Accuracy: 2F Per NSF C-2 >
2400 PANEL MOUNT E LEDA 110 Vac 080 8 FT 40/199 F0/250 2 1 / 2 ˝ MOUNTING PLATE2˝ MOUNTING2˝ PLATE 2410 PANEL MOUNT W/U-CLAMP B 220 Vac XXX SPECIAL LENGTH F40/120 Resolution: One degree >
F6. OPTION: 2˝ MOUNTING PLATE2400EA08040/199 C 24 Vac CXJ7XJ8 Update time: 3 readings per second >
(1) If power supply is not required change model number 2400 to 2401 or 2410 to 2411.(2) Not available on 2410 case. Sensitivity: At operating temperature, >
1 ⁄ >
2 F fluctua-tions in temperature are not indicated. >
How To Order (Typical Example) 8 TABLE 1TABLE 2
TABLE 3
TABLE 4
TABLE 5
TABLE 61. MODEL: DISPLAY2. DISPLAY: L.E.D.3. POWER: 110 Vac
4. LINE LENGTH: 8-00˝
5. TEMPERATURE RANGE: 40/199 Vibration: 50 to 200 Hz @ 2.5gno effect Failure Mode: Upscale >
www.ashcroft.com Dresser Industries, Dresser, Inc.250 East Main Street
Stratford, CT 06614
Tel: 203-378-8281 Fax: 203-385-0408 Copyright 2004 Dresser Instruments, Dresser, Inc. All rights reserved. 1P1/92 W/O-11/04