video corpo

Ash A2x
2Pages

{{requestButtons}}

Catalog excerpts

Ash A2x - 1

Model A2X Explosion/Flame Proof Pressure Transmitter Oil field equipment, upstream oil and gas production, natural gas compression and transfer control, alternative energy • Pressure ranges from 5 psi through • Six output signals to choose from • Optional absolute pressure ranges The Ashcroft® A2X pressure transmitter is ideal for a broad spectrum of pressure sensing requirements requiring approvals manufactured to provide the user with accurate, reliable, and stable output data. This is accomplished through the use of an on board microprocessor, that is pro- grammed during a unique digital compen- sation process, to provide extremely lin- ear and precise performance over the entire specified pressure and temperature PERFORMANCE SPECIFICATIONS Accuracy, Three Classes (% Span): ± 25 ±0.5 ±1.0 ncludes non-linearity (Terminal Point Method), hysteresis non-repeatability, zero offset and span setting errors Best Fit Straight Line* (BFSL): ±.20 ±.40 ±.50 nclucles non-linearity hysteresis, non-repeatability errors < ±0.25% Span/year® reference conditions Durability: Greater than 10 million cycles ENVIRONMENTAL SPECIFICATIONS Temperature Limits: 'Consult factory for other options • 1.0% of Span for .25% Accuracy Class • 2.0% of Span for .50% and 1.0% Accuracy Classes Humidity Effects: No performance effects from 0 to 95% relative humidity, non-condensing 'Consult factory FUNCTIONAL SPECIFICATIONS Pressure Ranges: Vacuum, gauge, compound and absolute pressure from 0-5 psi through 0-10,000. Equivalent ranges In bar available. See order guide section (reverse.) Vibration Effect: Position Effect: ± 0.02% Typical CE Mark (standard): EN 61326:1997 + A1 :1998 Annex A Heavy Industrial Immunity (Annex A, Table A.1) Light Industrial/Residential Emission (Table 4) Overpressure (F.S.)*: Proof Burst 'For higher overpressure ratings use XK8 option See page 2 for additional option. ELECTRICAL SPECIFICATIONS Output Signal: Supply Voltage: (unregulated) Minimum Maximum *30Vdc max for Intrinsically Safe Installations Power Requirements: Supply Current: <5mA forvoltage outputs Electrical Termination: 1/2 NPT male conduit with flying leads or shielded cable Circuit Protection: Reverse polarity and mis-wire proected Insulation Reslsance (Circuit to Case): 10OM oh m @ OOVrlc PHYSICAL SPECIFICATIONS Wetted Materials: 316L SS diaphragm and presure port, optional 17-4PH SS diaphragm and 316L SS pressure port Ingress Protection Rating: IP65; NEMA 7,9 HAZARDOUS AREA CERTIFICATIONS Explosion Proof -cUL (USL/CNL): Specify A2X Flame Proof-ATEX: Specify A2X NOTE: For4-20mA units following approvals also apply: Intrinsically Safe-FM/CSA: Refer to Ashcroft drawing #825A022 for wiring Refer to Ashcroft Model A2 for Heavy Industrial, non-Hazardous rated configurations and Ashcroft Model A4 for Intrinsically Safe/non-lncendive applications. All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA email: info@ashcroft.com • www.ashcroft.com

Open the catalog to page 1
Ash A2x - 2

Model A2X Explosion/Flame Proof Pressure Transmitter Pressure Fittings EXPLOSION / FLAME PROOF ENCLOSURE Load Limitations 4-20mA Output Only Loop Supply Voltage (Vdc) RL = Loop Resistance (ohms) Rs = Sense Resistance (ohms) Rw = Wiring Resistance (ohms) * (Includes a 10% safety factor) Proof Burst Refer to Ashcroft Model A2 for Heavy Industrial, non-Hazardous rated configurations and Ashcroft Model A4 for Intrinsically Safe/non-lncendlve applications. Accuracy /Temp. Effects Pressure Connection (others available upon request) Output Signal Ratio Metric ICVCR gland with Electrical...

Open the catalog to page 2

All ASHCROFT catalogs and technical brochures

  1. 5503

    2 Pages

  2. 1209

    3 Pages

  3. 1290

    2 Pages

  4. 2462

    2 Pages

  5. Type 1133

    2 Pages

  6. 302-303

    4 Pages

  7. T5500E

    2 Pages

  8. IXLDP

    2 Pages

  9. k1

    2 Pages

  10. K2

    2 Pages

  11. K8

    2 Pages

  12. km15

    2 Pages

  13. KS Sanitary

    2 Pages

  14. RXLDP

    2 Pages

  15. SL17-TTS

    1 Pages

  16. 600-01

    2 Pages

  17. 600-02

    2 Pages

  18. 600-03

    2 Pages

  19. 600-04

    2 Pages

  20. 600B

    2 Pages

  21. 600H

    2 Pages

  22. ar10

    4 Pages

  23. ar20

    4 Pages

  24. SWGL

    7 Pages

  25. sw10

    9 Pages

  26. A N4

    4 Pages

  27. A series

    8 Pages

  28. 600A

    2 Pages

  29. DT 600A

    2 Pages

  30. ash A4

    2 Pages

  31. A4

    2 Pages

  32. A2X

    2 Pages

  33. ASH DIG

    3 Pages

  34. DG 25

    3 Pages

  35. 1008S

    2 Pages

  36. 1008 A AL

    2 Pages

  37. 1125

    1 Pages

  38. 1009 1010

    1 Pages

  39. 1010

    2 Pages

  40. test gauges

    3 Pages

  41. 1259

    2 Pages

  42. Ash SW10

    9 Pages

  43. Ash SWA

    8 Pages

  44. Ash DG 25

    3 Pages

  45. Ash DG

    2 Pages

  46. Ash Bul

    3 Pages

  47. Ash EL

    2 Pages

  48. Ash BM

    2 Pages

  49. Ash A2 1 3

    2 Pages

Archived catalogs