Carbon monoxide NDIR analyzer for "in situ' measurements
4Pages

{{requestButtons}}

Catalog excerpts

Carbon monoxide NDIR analyzer for "in situ' measurements - 1

NDIR (Non Dispersive InfraRed) technology is recognized and accepted by the emission control authorities. ZCO analyzer uses a NDIR to assure a reliable, and long term accurate measurement of the average concentration of CO in the entire of the flue gases duct. situ” installation (directly stack) does not require sampling and treatment, equipment costs and maintenance reduced while very short response times are obtained. gas is necessary. control unit has a graphic for user friendly setting measuring range, threshold and operating mode. Combustion flue gases CO analyzer: Quick installation Easy calibration Reduced maintenance ISO 9001 Certifified E

Open the catalog to page 1
Carbon monoxide NDIR analyzer for "in situ' measurements - 2

2m connection cable Control unit 1 analog input + 1 analog ouput 1 digital input + 2 digital outputs 115/230 Vac for measurement parameterization, compensation can means of a signal or by value with the measurement can be mg/Nm3. When the ZCO-IGM-901 can be used characteristics at measurement point Receiver location location 2 Gas flow: homogeneous Gas temperature: 300°C (higher temperatures on request) Dust concentration: 1g/m3 x m. Flanged connections are suitable for welding on steel ducts (other materials on request or provided by the customer). To avoid to loose the alignment, the duct...

Open the catalog to page 2
Carbon monoxide NDIR analyzer for "in situ' measurements - 3

Protection IP65 Sender/receiver cable length 15m Receiver/control unit cable length 2m + 5m extension cable (10 or 15m optional) Instrument air supply Pressure: 2 mbar more than the stack pressure Consumption: 30 m3/h max. Options 10/15 m extension cable for receiver/control unit connection (max. distance without repeater 2 + 15 m) Sender/Receiver alignment unit Conformities and certifications Conformities EMC specifications in accordance with EN 50081-1 and EN 50082-2 VDE Guidelines pursuant to EN 61010 (IEC 1010-1, VDE 0411), class of protection 1, Certifications degree of protection IP65...

Open the catalog to page 3
Carbon monoxide NDIR analyzer for "in situ' measurements - 4

Accessories: Ordering code Receiver/control unit extension cable, 10 m AZCPROLUNGA10M Receiver/control unit extension cable, 15 m AZCPROLUNGA15M Sender/receiver alignment unit AZC2020436 Purge air unit [1] AZCSOFFIANTE230 Purge air unit [2] AZCSOFFIANTE400 Notes: [1] 0.37 kW - 230 Vac - 50 Hz single phase [2] 0.37 kW - 400 Vac - 50 Hz three phase 4 64 30 62 62 64 30 84 98 fr france@ascon.fr 74 27 82 81 74 27 81 71 CORPORATION Ridgelawn Trail Illinois 60510 482 2950 482 2956 asconcorp.com asconcorp.com NETWORK OF CENTERS, AND VARs Czech Rep., Esthonia, Finland, France, Britain, Greece,...

Open the catalog to page 4

All ASCON TECNOLOGIC catalogs and technical brochures

  1. NP4

    2 Pages

  2. TRH-MINI

    3 Pages

  3. TRH52

    4 Pages

  4. TRH21

    4 Pages

  5. KR1E

    4 Pages

  6. ClimaPAC

    8 Pages

  7. at on cloud

    8 Pages

  8. TCPDE M

    2 Pages

  9. opmt

    2 Pages

  10. m81

    6 Pages

  11. MP02

    2 Pages

  12. IO-CB series

    4 Pages

Archived catalogs