cad

Catalogue-Accessories-Dust Collector-909
4Pages

{{requestButtons}}

Catalog excerpts

Catalogue-Accessories-Dust Collector-909 - 1

SEQUENCERS FOR DUST COLLECTOR SYSTEMS without internal AP pressure sensor for the control of up to 48 solenoid valves FEATURES • Electronic controller for the control of solenoid valves in dust collector systems • ON/OFF filter cleaning cycle from external switch • Microprocessor management • Supply and output voltage selectable via jumper • 3 programming keys • 3 digit LED display • Adjustable pulse and interval times • Automatic detection of number of valves • Additional post-cleaning cycle mode • High immunity from external interference • Short-circuit protection of every single output • 1 output relay (e.g. group alarm), 2 digital inputs (volt-free) Housing ABS (acryl nitrile butadiene styrene), grey Cover PC (polycarbonate), transparent ELECTRICAL CHARACTERISTICS Standard supply voltage AC (~) 230/115 V Output voltage DC (=) 24 V Other voltages on request. 60300GB-2016/R01 Availability, design and specifications are subject to change without notice. All rights reserved. All leaflets are available on: www.asconumatics.eu

Open the catalog to page 1
Catalogue-Accessories-Dust Collector-909 - 2

SEQUENCERS FOR DUST COLLECTOR SYSTEMS SERIES E909 OPTIONS (on request) Other voltage ratings, other housings and devices with ATEX approval Installation/maintenance instructions are included with each sequencer DIMENSIONS (mm), WEIGHTS Sizes 1 and 2 60300GB-2010/R01 Availability, design and specifications are subject to change without notice. All rights reserved. All leaflets are available on: www.asconumatics.eu 6

Open the catalog to page 2
Catalogue-Accessories-Dust Collector-909 - 3

SEQUENCERS FOR DUST COLLECTOR SYSTEMS SERIES E909 ADDITIONAL CYCLES BY CONTACT FROM FAN (contact closed = fan ON) NOTE: link clamps if not used with inputs from external contact enabled (F01=0) ON/OFF CLEANING CYCLE BY EXTERNAL CONTACT/PRESSURE SWITCH D6 WITH F07=1, C6 WITH F07=0 (contact closed = cycle enabled) NOTE: link clamps if not used with inputs from external contact enabled (F01=0) CUMULATIVE ALARM RELAY EARTH COMMON OUTPUT NUMBER SUPPLY VOLTAGE 1 Phase 2 Neutral 3 Earth See technical features POWER SWITCH (option) WIRING DIAGRAM OUTPUT VOLTAGE FOR ELECTRO-VALVES See technical...

Open the catalog to page 3
Catalogue-Accessories-Dust Collector-909 - 4

60300GB-2010/R01 Availability, design and specifications are subject to change without notice. All rights reserved. SEQUENCERS FOR DUST COLLECTOR SYSTEMS SERIES E909 All leaflets are available on: www.asconumatics.eu

Open the catalog to page 4

All ASCO catalogs and technical brochures

  1. 908 series

    2 Pages

  2. Accessories

    2 Pages

  3. Oil and gaz

    12 Pages