2/2 4
Brass Body • 3/8" to 1" NPT
8238
The 8238 Series is a 2-way pilot operated valve available inNormally Closed and Normally Open constructions. They are
available either AC or DC operated with brass bodies. They
come standard with Din connection coils. Options are limited to
flying leads, manual operators, and some alternate elastomers.
Dedicated constructions of the 8238 Series are suitable for the
following applications:• General Service (air, inert gas, water, and light oil)
)
CUS
&
Construction
Electrical
Valve Parts in Contact with Fluids General Service Body Brass Seals and Discs as listed Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Shading Coil Copper >
NCNO
Watt Rating and Power Consumption DINSpare CoilFamily Standard Coil Class of Insulation AC DINConnectionSize DC Watts VA Holding VAInrush AmbientTemp.ËšF Watts AC/DC F 5.5 4 6 12 15 to 140 4300 11 mm F 6.0 6.0 10 16 15 to 140 Z614A 11 mm F 9.2 9.2 14 23 15 to 140 ZA34A 18 mm F 13.0 13.0 24 44 15 to 140 Z134A 18 mm F 17.2 17.2 27 50 15 to 140 Z914A 18 mm F - 21.0 33 65 15 to 140 Z923E 18 mm Standard Voltages: 24, 120, 240 volts AC, 60 Hz (or 110, 230 volts AC, 50 Hz). 12, 24 volts DC (6 DC for 3 watt version). Must be specified when ordering. >
Approvals
UL recognized coilMeets applicable CE directives 1