95006007/6/04E
Datasheet Type
Technical data
Ex-classification: Operating temperature: Operating pressure: Self monitoring: Mounting connection: Mounting length: Material wet side:
Control system types: Inline sterilization possible
Options
AF42 / AF42 LL
EEx ia IIC T4 -30°C to 80°C -0.5 bar to 20 bar Yes G1"
According to customer spec. 1.4435, Quartz-Glass
AS1, AS8, AS9, AN3, AN9, AS51-E24, AS83-E24, AS9-E24
Mounting connection G 1", 1.4435
Connector box, aluminium with clamps and PG
Connector box, aluminium with Bendix connection
As AF42 in Hastelloy execution
Execution with fibre optic (type LL)
Execution in PTFE
Aquasant AG Ph: +41 (0)56 437 4080
Schartenstrasse 111 page 1 of 2 Fax: +41 (0)56 437 4089
CH-5430 Wettingen with reservation of technical modifications Information@aquasant.com
Switzerland www.aquasant.com 6/04
|
|