You may also be interested in
Turbidity meter, Level controller, Level switch, Controller, Turbidity sensor
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:6.00pt "Arial", sans-serif; }
.font1 { font:8.00pt "Arial", sans-serif; }
.font2 { font:9.00pt "Arial", sans-serif; }
95006030/6/04E
Datasheet Type
Lugan 1000 PP
Technical data:
Flow capacity: Dimensions H x W x D:
Weight:
Mains connection: Air requirement: Water temperature: Feed pump:
1250 l/h
1800 x 1040 x 530 mm
130 kg
230 V/15 A (Residual current operated circuit breaker) 4 - 6 bar, approx. 50 l/h 4°C - 60°C
1.5 m3 at 15 m Wg, 230 V / 50 Hz, with special suction basked and check valve
Process pump IP 65 Pipe work PVC
Process container (integrated in the decanter) Manometer
Dosing places with metering valve
Process cycle equiped with:
Decanter with reaction and water Sampling discharge water trap inclusive:
Control:
Pneumatic outlet valve
Pipe for the discharge water
Hand valve for emptying of decanter
Opening for decanter cleaning
Dosing places inclusive metering valves
Overflow adjustable
Mains contact 230 V / 50 Hz, 10 A
Level control min. / max.
Level control high alarm
Air pressure control
Flocculation liquid min.level control
Mud container high alarm control
Controls of all pumps, valves and dosing pumps
Delay for outlet valve adjustable (Bypass)
Clamps wired and ready for installation
LED, keys and switches all in front
Mud bag rack:
Galvanized steel
Aquasant AG page 1 of 3 Ph: +41 (0)56 437 4080
Schartenstrasse 111 with reservation of technical modification Fax: +41 (0)56 437 4089
CH-5430 Wettingen www.aquasant.com Information@aquasant.com
Switzerland 6/04
|
|