THERMYS 150 - 1

Advanced field documenting thermometer / temperature calibrator THERMYS 150 is an all-in-one high accurate documenting thermometer / temperature calibrator for thermocouples (14 types), resistive probes (12 types) and thermistors with a high accuracy of up to 0.005% RDG.

Open the catalog to page 1
THERMYS 150 - 2

Description THERMYS 150 is an all-in-one high accurate documenting thermometer / temperature calibrator for thermocouples (14 types), resistive probes (12 types) and thermistors with a high accuracy: Thermocouples: Up to 0.005% RDG RTDs: Up to 0.006% RDG Thermistors: Up to 0.006% RDG It is designed for field and lab use for advanced temperature maintenance and use on test bench in all industries. Simultaneous measurement and emission of temperature (IN / OUT) Simultaneous measurement over two channels for comparison calibration (IN / IN) The second channel can be used either for temperature...

Open the catalog to page 2
THERMYS 150 - 3

Easy connection system Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors. Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.

Open the catalog to page 3
THERMYS 150 - 4

Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading (THERMYS 150 display) + fixed value. Resistive probes: Measurement and simulation Sensor Range (Input and Output) Accuracy / 1 year (Measurement) Accuracy / 1 year (Simulation) Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Take into account particular error of temperature sensor used and implementation conditions Admissible measuring current: 0.01 mA to 1...

Open the catalog to page 4
THERMYS 150 - 5

Temperature coefficient: < 10% of accuracy /°C Thermocouples: Measurement and simulation Type Input range Resolution Accuracy / Output 1 year (Me range asurement) Accuracy / 1 year (Simulation )

Open the catalog to page 5
THERMYS 150 - 6

Thermocouples: PlatineL, Mo, NiMo/NiCo, G, D, L, C: For specifications, refer to the instruction manual (Available on request) Accuracy is given for reference @ 0°C. When using the internal reference junction (except couple B) add an additional uncertainty of 0.2 °C at 0 °C. It is possible (thermocouple B excepted) to choose by programming the cold junction localization: External at 0°C, internal (temperature compensation of instrument’s terminals) or manually entered. Temperature coefficient: <10% of accuracy /°C Display unit: °C and F. Thermistors: Measurement and simulation With 50 Kohms...

Open the catalog to page 6
THERMYS 150 - 7

% of FS or in all other units. This function also allows sensors to be corrected after a calibration. Relative measurement The features allows the following : Programming a reference value different from the one of the instrument (NUL function). Subtracting of constant value by measuring or programming it from a measured value (TARE function). Simulation menu Simulation value is set by entering value on keypad or by changing the specific digit with the cursor. Square root In current measurement and simulation, this function allows taking into account a quadratic signal coming from...

Open the catalog to page 7
THERMYS 150 - 8

General specifications Size 240 x 320 pixel liquid crystal graphical display with backlite and contrast control Display of result as table of values or trend curve Power supply Type: Temps de charge: h Endurance : 5,000 mesures à 10 A Communication ports Storage capacity Up to 10 full configurations (Input / output type, range…) 10,000 data into one or several measurement campaigns, i.e. more than one week work with configurations, measurements, calibration procedures and reports Environmental specifications Reference range Operating reference range Limit operating range Storage temperature...

Open the catalog to page 8
THERMYS 150 - 9

Conducted and radiated emissions:

Open the catalog to page 9
THERMYS 150 - 10

Models and accessories Instrument: THERMYS150 On-site high accurate documenting temperature calibrator / thermometer Delivered in standard with: User manual Battery charger Set of 6 testing leads Carrying strap Factory test report Transport case for CALYS series Set of 6 measuring cables with removable crocodile clips Cable to drive temperature dry blocks and baths for CALYS 150 Please ask before for compliance with your bath/dry block Software: DATACAL Calibration software for CALYS 75 / 100 / 150 Supplied with USB cable COFRAC certificate of calibration With all relevant data points where...

Open the catalog to page 10

All AOIP catalogs and technical brochures

  1. RAYOMATIC 16

    7 Pages

  2. RLV

    5 Pages

  3. EPM

    10 Pages

  4. UNIGAS 3000

    7 Pages

  5. RN 5306

    5 Pages

  6. TTI 10

    6 Pages

  7. RN 5360

    5 Pages

  8. MEGOHM 200

    7 Pages

  9. MF 28

    6 Pages

  10. CALYS 1000

    7 Pages

  11. IND 45

    6 Pages

  12. CALYS 1500

    12 Pages

  13. RAYOMATIC PE

    6 Pages

  14. IRTEC P IVT

    5 Pages

  15. RAYOMATIC TC

    6 Pages

  16. ICO 51

    6 Pages

  17. LKS 1000

    5 Pages

  18. MILLIK

    7 Pages

  19. TC 6621 / 6622

    10 Pages

  20. SN 8310

    7 Pages

  21. CALYS 60 IS

    9 Pages

  22. CP 6632

    7 Pages

  23. CALYS 120 IS

    12 Pages

  24. ZX

    5 Pages

  25. OM 10

    6 Pages

  26. OM 21

    8 Pages

  27. ISOPALM 200

    7 Pages

  28. CRIT 100

    4 Pages

  29. IRtec P

    11 Pages

  30. FD 5 / 10 / 15

    12 Pages

  31. VNE20

    5 Pages

  32. OM 16

    8 Pages

  33. CALYS 80 IS

    11 Pages

  34. CALYS 80P

    10 Pages

  35. P200 PRO

    8 Pages

  36. CALYS 150

    8 Pages