Benchtop DC voltage and current source standard with high accuracy of 0.002% SN 8310 is a standard DC voltage and current source. It supplies voltages from 100 nV to 110 V and currents from 1 nA to 110 mA with an accuracy of better than 0.002% (20 ppm).
Open the catalog to page 1Description SN 8310 is a standard DC voltage and current source. It supplies voltages from 100 nV to 110 V and currents from 1 nA to 110 mA with an accuracy of better than 0.002% (20 ppm). It is fully programmable via RS 232 and IEEE 488 (option) interfaces, which makes it the perfect instrument for test benches and automatic test equipment applications. SN 8310 is also available with a battery in option. SN 8310 is offered into a compact benchtop housing for on-site use as well as benchtop or panel mounted use. It is widely used in metrological departments, quality-control departments,...
Open the catalog to page 2Specifications Specifications and performances in process @23°C ±1°C DC current: Emission Range Emission range Compliance, output impedance, stability, noise data Range Compliance with positive output Compliance Output with impedance negative output (1) Power delivered by instrument is limited to 1.4 W approximately. (2) Maximum output voltage can be limited to 25 V. Temperature Coefficient < 10% accuracy /°C Warm-up time: - 30 s to generate an output within 0.002% of final value - 5 min to get an output within 0.0002% of final value Linearity: < 0.0003% of range Max output voltage: 30 V...
Open the catalog to page 3Compliance with positive output Compliance Output with impedance negative output (1) Power delivered by instrument is limited to 1.4 W approximately. Temperature Coefficient < 10% accuracy /°C Warm-up time: - 30 s to generate an output within 0.002% of final value - 5 min to get an output within 0.0002% of final value Linearity: < 0.0003% of range Max output voltage: 30 V Possible external supply: ≤ 30 V Overshoot: < 5% Further features Step simulation Manual or automatic generation of user programmable steps Generation of programmed values Emission of 200 calibration values recalled: - Via...
Open the catalog to page 4Environmental specifications Reference range Operating reference range Limit operating range Storage temperature limits -30°C to +55°C (-15 to +50°C for model with battery charged) Safety specifications Class In accordance with EN 61010-1 Category III, pollution 2 Rated voltage EN 61000-4-4 Conducted and radiated emissions: EN 55022, class B EN 61000-3-2 EN 61000-3-3
Open the catalog to page 5SN8310-1 DC voltage and current standard generator Delivered in standard with: • Carrying case • Factory test report SN8310-2 DC voltage and current standard generator Delivered in standard with: • Carrying case • Factory test report SN83101-3 DC voltage and current standard generator Delivered in standard with: • Carrying case • Factory test report SN8310-4 DC voltage and current standard generator Delivered in standard with: • Carrying case • Factory test report AN6901 Soft case for benchtop instruments AN5883 Bracket mounting for panel installation (T2 box type) AN5884 Rack mounting kit...
Open the catalog to page 6Data management software for SN 8310 COFRAC certificate of calibration With all relevant data points where the device has been tested Packing information: Size Weight (gross) 255 x 88 x 310 mm 2 to 3 kg according to the configuration chosen
Open the catalog to page 7All AOIP catalogs and technical brochures
-
RAYOMATIC 16
7 Pages
-
RLV
5 Pages
-
EPM
10 Pages
-
UNIGAS 3000
7 Pages
-
RN 5306
5 Pages
-
LKS 1000 Leakshooter camera
6 Pages
-
TTI 10
6 Pages
-
RN 5360
5 Pages
-
MEGOHM 200
7 Pages
-
MF 28
6 Pages
-
CALYS 1000
7 Pages
-
IND 45
6 Pages
-
CALYS 1500
12 Pages
-
RAYOMATIC USB 2.2
6 Pages
-
RAYOMATIC PE
6 Pages
-
RAYOMATIC USB
6 Pages
-
IRTEC P IVT
5 Pages
-
RAYOMATIC 16 2.2
6 Pages
-
RAYOMATIC NET
6 Pages
-
RAYOMATIC TC
6 Pages
-
ICO 51
6 Pages
-
LKS 1000
5 Pages
-
MILLIK
7 Pages
-
TM 6602 / 6612 / 6630
8 Pages
-
TC 6621 / 6622
10 Pages
-
CALYS 60 IS
9 Pages
-
CP 6632
7 Pages
-
THERMYS 150
10 Pages
-
CALYS 120 IS
12 Pages
-
ZX
5 Pages
-
OM 10
6 Pages
-
OM 21
8 Pages
-
ISOPALM 200
7 Pages
-
CRIT 100
4 Pages
-
IRtec P
11 Pages
-
FD 5 / 10 / 15
12 Pages
-
VNE20
5 Pages
-
OM 16
8 Pages
-
SATURN CYCLOP 878
4 Pages
-
CALYS 80 IS
11 Pages
-
CALYS 80P
10 Pages
-
P200 PRO
8 Pages
-
CALYS 150
8 Pages
-
motor starter
4 Pages
-
Frontdaq 10 isolated channels
4 Pages
-
Data Acquisition Systems DATALOG
12 Pages
-
Accuracy Thermometer PHP 602
2 Pages