PMA 5 Pensky-Martens Flash Point Tester - 8 Pages

Add to MyDirectIndustry favorites
PMA 5 Pensky-Martens Flash Point Tester

Catalog excerpts

A Tradition of Competence 140 years of developing, producing and supporting excellent flammability instruments. 140 years of technology lie between the first flash point tester and today’s Anton Paar product line of flammability measuring instruments. Mr. Berthold Pensky developed the first closedcup flash point tester and set a milestone for the production of flash point testers based on quality and precision. Aligned to the requirements of varying industrial branches the instruments from Berlin could meet a worldwide demand. The acquisition of Petrotest by Anton Paar combines the spirit...

 Open the catalog to page 2

Flash Point Measurement All methods – all standards – one product line Anton Paar has the suitable flammability tester for each type of measuring task in its product line. Tests according to 4 standardized methods in the temperature range of -30 °C to 400 °C are possible to cover a wide range of applications. This includes: the petrochemical field, calibration and regulation authorities, transportation and shipping, engineering, waste management and the cosmetics and food industries. Cleveland method … … open-cup determination for expected flash and fire points in the range of 79 °C to 400...

 Open the catalog to page 3

PMA 5 Make Work Easy and Safe Patented error-free connection The One-Twist patented swivel-around multi-functionhead guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter actuator, stirrer, igniter and detector contacts. It reduces the set-up time after a sample change and assures comfortable and error-free handling. Immersion depth to perfection The multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth. Available with glass or stainless steel temperature probe and...

 Open the catalog to page 4

Choice of ignition The PMA 5 allows the use of an electric or gas igniter. If working with the gas ignition, the electric igniter is used as an auxiliary ignition to ensure the uninterrupted burning of the test flame. If necessary it relights the flame during the test automatically. Being independent of a gas source allows more mobility and extends the application range. Fire hazard reduced to zero The integrated fire-extinguishing system is automatically controlled or can be released manually. Flames that might occur outside the cup will be extinguished by nitrogen or carbon dioxide gas....

 Open the catalog to page 5

Software FPPNet This optional software allows a computer connection for direct control and real-time monitoring of the test progress. It is a convenient solution for test data evaluation and documentation. Further, it simplifies firmware updates and the export of test results. On-site calibration The calibration set PMA/PM is a mandatory accessory for the PMA 5 calibration programs. It is used to calibrate the sample Pt100 dynamically against certified thermometers. The on-site calibration feature is very cost-effective and available at any time. Multi-detector functionality check The...

 Open the catalog to page 6

Specifications Flash point determination Standard methods The temperature in non-equilibrium methods is increased slowly over a given range with the source of ignition being presented to the vapor at intervals until the flash is observed. The flash point is the lowest temperature, corrected to a barometric pressure of 101.3 kPa, at which application of an ignition source causes the vapors of a specimen of the sample to ignite under specified conditions of the test. Pensky-Martens methods for petroleum products: ASTM D93 A+B+C, ISO 2719 A+B, ISO 15267, JIS K 2265-3, IP 34 A+B, GOST R EN ISO...

 Open the catalog to page 7

Subject to change without notice 07/14 H03IP001EN-D

 Open the catalog to page 8

All Anton Paar catalogs and technical brochures

  1. Tribometers

    7 Pages

  2. TTK 600

    2 Pages

  3. ViscoQC

    2 Pages

  4. Vstar

    8 Pages

  5. Monowave 400

    2 Pages

  6. AP Stage Mover

    2 Pages

  7. Snap 51

    2 Pages

  8. Snap 41

    1 Pages

  9. Anton paar

    3 Pages

  10. Multiwave Go

    8 Pages

  11. SAXSpoint 2.0

    16 Pages

  12. RheoSAXS

    3 Pages

  13. General Catalog

    31 Pages

  14. Cobrix 2600

    3 Pages

  15. DHS 1100

    2 Pages

  16. Abbemat T-Check

    2 Pages

  17. Tribometer

    7 Pages

  18. Alex 500

    6 Pages

  19. PSA Series

    8 Pages

  20. SmartPave

    12 Pages

  21. Alcolyzer ME

    2 Pages

  22. Propol

    2 Pages

  23. Alex 500 Wine

    6 Pages

  24. PetroOxy

    2 Pages

  25. PM 4

    2 Pages

  26. CLA 5

    2 Pages

  27. ADU 5

    2 Pages

  28. ABA 4

    2 Pages

  29. Foam Tester

    2 Pages

  30. PNR 12

    2 Pages

  31. BPA 5

    2 Pages

  32. Alex 500

    2 Pages

  33. OBA 2

    2 Pages

  34. TOST & TOO

    2 Pages

  35. OBA 1

    2 Pages

  36. DD 3

    2 Pages

  37. Grease Worker

    2 Pages

  38. DDA 3

    2 Pages