MCR Temperature Devices - 11 Pages

Add to MyDirectIndustry favorites
MCR Temperature Devices

Catalog excerpts

Temperature Devices

 Open the catalog to page 1

Ready for the greatest influence of all. Certaint ■ you control the greatest rheological influence of all: temperature. Choose from a vast range of temperature devices to combine with your MCR rheometer and rely on the high-precision temperature control required for truly accurate rheological results. Innovation. State-of-the art production techniques like 3D metal printing bring temperature control to the next level. The unique design of the inner shells of the CTD 600 MDR convection temperature device, which are manufactured as one piece each, results in absolutely homogeneous temperature...

 Open the catalog to page 2

Modular Temperature Control … … from -160 °C to 1000 °C Page Anton Paar’s temperature control portfolio is sure to contain a specific solution for your application. Here are all relevant parameters for your consideration – and the symbols with which they are presented in this brochure. Which range of temperature do you require? I want to measure around room temperature 14-17 I want full flexibility I want to measure above 200 °C Which materials are you going to measure? These symbols are used to give you a first impression of each temperature device’s area of application. Which measuring...

 Open the catalog to page 3

I Want to Measure Around Room Temperature Rheology is an important factor in many application and production processes that take place around room Liquid temperature control for concentric-cylinder systems temperature. Measurements in this field essentially rely on precise temperature setting that is independent from Recommended for measurements at constant temperatures outside conditions. Temperature range depends on the In the following, find cost-effective temperature Temperature measurement close to the sample control solutions from Anton Paar that cover the range XL version for liquids...

 Open the catalog to page 4

I Want to Measure Up to 200 °C To fully investigate the rheological properties of your sample, you usually require measurements at low and high temperatures, as well as the possibility to perform temperature ramps. Peltier temperature control for concentric-cylinder systems These requirements are met by the following Anton Paar High heating and cooling rates temperature devices, which cover a wide temperature range No vertical temperature gradients in sample due to based on a convenient cooling option that does not require patented thermal transfer system (US Patent 6,240,770) Fluid...

 Open the catalog to page 5

I Want to Measure Up to 200 °C without a cover, with a passive cover and show that only a hood with temperature with an actively heated hood. control can provide the temperature The figures below show the temperature The temperature differences were measured accuracy required for successful rheological distribution between the upper and lower in a thermoplast sample at a measuring surface of a sample temperature-controlled temperature of 100 °C. The tests clearly Avoiding temperature gradients Open system ∆T = 14.5 °C in the sample System with passive insulating hood Advanced Peltier System...

 Open the catalog to page 6

Materials like typical polymer melts are usually measured in a temperature range from 170 °C to 280 °C. In case the glass transition of the material is of interest, temperatures below room might be required as well. Benefit from specific Anton Paar solutions for these applications and use one single temperature device to operate in a range from -150 °C to 400 °C. Typical applications above 200 °C Polymer melts, epoxy resins C-ETD 300 30 °C/min 3 °C/min Useful accessories... C-ETD 300 ElebtricaTtemperature control for concentric-cylinder systems ► Temperature device for Standard Pressure...

 Open the catalog to page 7

I Want Full Flexibility Rheological characterizations are performed on all kinds Convection temperature devices: of materials, from low-viscosity liquids up to solids. To General features fixtures, tribological accessories, UV curing option, and dielectric spectroscopy measure different kinds of samples, you require a variety Low temperature option: Measurements with Temperature control with perfectly homogeneous gas of different measuring systems, and in addition you might optimized liquid nitrogen consumption depending flow within the system and thus high accuracy due to also be...

 Open the catalog to page 8

CTD 600 MDR - 3D printed State-of-the-art temperature control based on combined convection and radiation ► Innovative 3D metal printing production technology: the inner shells are manufactured as one piece each, resulting in a unique homogenous temperature distribution within the oven ► Error-proofing due to preset flow rates ► Suitable for DMA in torsion, DMA in extension, photo DMA (UV curing), extensional rheology (SER), tribological (T-BTP), and dielectric (DRD CTD) investigations ► Integrated non-reflecting interior LED-illumination for checking the sample during the measurement ►...

 Open the catalog to page 9

Four Principles Working for You Countercooling Peltier element Measuring plate Measuring plate Measuring plate Sample Cooling Hood Heating plate Measuring plate Hood Heating plate Measuring plate Measuring plate Measuring plate Peltier element Liquid temperature control Peltier temperature control Electrical temperature control Convection temperature control Fluid circulators are an established solution for accurate Peltier systems have a number of advantages over other Electrical temperature control is mainly used for higher The high-performance convection temperature devices are...

 Open the catalog to page 10

© 2017 Anton Paar GmbH | All rights reserved. Specifications subject to change without notice. C92IP003EN-L

 Open the catalog to page 11

All Anton Paar catalogs and technical brochures

  1. Tribometers

    7 Pages

  2. TTK 600

    2 Pages

  3. ViscoQC

    2 Pages

  4. Vstar

    8 Pages

  5. Monowave 400

    2 Pages

  6. AP Stage Mover

    2 Pages

  7. Snap 51

    2 Pages

  8. Snap 41

    1 Pages

  9. Anton paar

    3 Pages

  10. Multiwave Go

    8 Pages

  11. SAXSpoint 2.0

    16 Pages

  12. RheoSAXS

    3 Pages

  13. General Catalog

    31 Pages

  14. Cobrix 2600

    3 Pages

  15. DHS 1100

    2 Pages

  16. Abbemat T-Check

    2 Pages

  17. Tribometer

    7 Pages

  18. Alex 500

    6 Pages

  19. PSA Series

    8 Pages

  20. SmartPave

    12 Pages

  21. Alcolyzer ME

    2 Pages

  22. Propol

    2 Pages

  23. Alex 500 Wine

    6 Pages

  24. PetroOxy

    2 Pages

  25. PM 4

    2 Pages

  26. CLA 5

    2 Pages

  27. ADU 5

    2 Pages

  28. ABA 4

    2 Pages

  29. Foam Tester

    2 Pages

  30. PNR 12

    2 Pages

  31. BPA 5

    2 Pages

  32. Alex 500

    2 Pages

  33. OBA 2

    2 Pages

  34. TOST & TOO

    2 Pages

  35. OBA 1

    2 Pages

  36. DD 3

    2 Pages

  37. Grease Worker

    2 Pages

  38. DDA 3

    2 Pages