Instruments for Chemical and Petroleum Products - 12 Pages

Add to MyDirectIndustry favorites
Instruments for Chemical and Petroleum Products

Catalog excerpts

Flash Point Instruments for Chemical and Petroleum Products

 Open the catalog to page 1

140 years of technological advances lie between the first flash point tester and today’s Anton Paar product line of flammability measuring instruments. Mr. Berthold Pensky developed the first closed-cup flash point tester and set a milestone for the production of high-quality and high-precision flash point testers. Aligned to the requirements of various industrial branches the instruments from Berlin met a worldwide demand. The acquisition of Petrotest by Anton Paar resulted in the combination of the spirit of research and inventive talent with the advantages of a...

 Open the catalog to page 2

Flash Point Measurement All methods – all standards – one product line Anton Paar has the suitable flammability tester for each type of measuring task in its product line. Tests according to standardized methods in the temperature range of -30 °C to 400 °C are possible to cover a wide range of applications. This includes: the petrochemical field, calibration and regulation authorities, transportation and shipping, engineering, waste management and the cosmetics and food industries. Cleveland method … … open-cup determination for expecting flash and fire point in the range of 79 °C to 400 °C...

 Open the catalog to page 3

ABA 4 Abel Flash Point Tester Standard methods Abel flash point:    ISO 13736, IP 170 Equilibrium procedure:    ISO 1523, IP 492, EN 924 TAG 4 Tag Flash Point Tester Standard methods Tag flash point:    ASTM D56, FTM 791-1101 Equilibrium procedure:    ASTM D3941, ISO 1523, Benefits at a Glance ► Two cooling systems with Peltier elements according to the ISO 13736 standard: an economical air-cooled model and a low-temperature version with external water cooling ► The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition...

 Open the catalog to page 4

Standard methods    Standard methods Pensky-Martens methods for petroleum products:    ASTM D92, ISO 2592, JIS K 2265-4, AASHTO T48, ASTM D93 A+B+C, ISO 2719 A+B+C, JIS K 2265-3 A+B,    FTM 791-1103, IP 36, GOST 4333 Benefits at a Glance ► Integrated fire-extinguishing system automatically controlled or manually released (requires N2 or CO2 gas) ► The One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter release, stirrer, igniter and detector contacts ► A multi-detector combines the flash point detector...

 Open the catalog to page 5

Versatility by Options PMA 4 SC Sample Changer The Pensky-Martens closed-cup tester with sample changer measures the flash point of up to 12 samples automatically. PMA 4 SC is suitable for flammability applications on both biodiesel and biodiesel blended fuels along with diesel, heating oil and kerosene. It is also commonly used for other potentially flammable liquids. PMA 4 SC On-site calibration The calibration set is a mandatory accessory for all flash point tester calibration programs. It is used to calibrate the sample temperature sensor Pt100 dynamically against certified...

 Open the catalog to page 6

flash point testers The software serves the purpose of reading and evaluating test data as well as controlling the automatic flash point testers PMA 5, CLA 5, ABA 4, TAG 4, PMA 4 SC (sample changer version) and their previous models (PMA 4, CLA 4). It is easy to operate, with self explanatory menus.The flash point tester is connected to the PC-RS232 interface by using a null modem cable or the USB port. Benefits at a Glance ► Monitoring of real-time test progress on the PC screen ► Traceable documentation of all parameter adjustments ► Graphical display of the sample temperature,...

 Open the catalog to page 7

Technical specifications ABA 4    ITAG 4 Test programs    Abel flash point: ISO 13736, IP 170 | Equilibrium proce- Tag flash point: ASTM D56, FTM 791-1101 | Equilibrium dures: ISO 1523, IP 492, EN 924 | ISO 1516, IP 491 |    procedures: ASTM D3941, ISO 1523, IP 492, EN 924 | Optional Abel-Pensky: DIN 51755-1 | 2 individually    ASTM D3934, ISO 1516, IP 491 | 2 individually design- designable test programs    able test programs

 Open the catalog to page 8

Test programs    ASTM D93 A+B+C | ISO 2719 A+B+C | JIS 2265-3 A+B | ASTM D92 | ISO 2592 | JIS K 2265-4 | AASHTO T48 | IP 34 A+B | GOST R EN ISO 2719 | 15 individually FTM 791-1103 | IP 36 | GOST 4333 | 10 individually designable test programs    designable test programs Safety    Overheat protection, automatic shut-off | Automated fire- Overheat protection, automatic shut-off | Test aborted extinguishing system | A potential-free alarm relay contact by warning message is also available to connect a fire suppression or remote alarm system | Password protection | Detects a "flash" outside the...

 Open the catalog to page 9

PMA 4 SC Standard Methods ASTM D93 A+B+C, ISO 2719 A+B+C, JIS K 2265-3, IP 34 A+B Technical Specifications

 Open the catalog to page 10

Go Beyond the Conventional Scope Extended Measuring Range for ABA 4 and TAG 4 Thanks to state-of-the-art Peltier element technology two cooling versions are available for ABA 4 and TAG 4: an economical version with internal air cooling for flash point measurements from +10 °C to +110 °C and and a low-temperature version with a low-cost external liquid cooling from -30 °C to +110 °C. This enables you to go beyond the conventional scope of the method. ABA 4 and TAG 4 are suitable for flash point applications on jet fuels, solvents, chemicals etc. and give you the choice between gas or...

 Open the catalog to page 11

© 2017 Anton Paar GmbH | All rights reserved. Specifications subject to change without notice. XPTIP005EN-C

 Open the catalog to page 12

All Anton Paar catalogs and technical brochures

  1. Tribometers

    7 Pages

  2. TTK 600

    2 Pages

  3. ViscoQC

    2 Pages

  4. Vstar

    8 Pages

  5. Monowave 400

    2 Pages

  6. AP Stage Mover

    2 Pages

  7. Snap 51

    2 Pages

  8. Snap 41

    1 Pages

  9. Anton paar

    3 Pages

  10. Multiwave Go

    8 Pages

  11. SAXSpoint 2.0

    16 Pages

  12. RheoSAXS

    3 Pages

  13. General Catalog

    31 Pages

  14. Cobrix 2600

    3 Pages

  15. DHS 1100

    2 Pages

  16. Abbemat T-Check

    2 Pages

  17. Tribometer

    7 Pages

  18. Alex 500

    6 Pages

  19. PSA Series

    8 Pages

  20. SmartPave

    12 Pages

  21. Alcolyzer ME

    2 Pages

  22. Propol

    2 Pages

  23. Alex 500 Wine

    6 Pages

  24. PetroOxy

    2 Pages

  25. PM 4

    2 Pages

  26. CLA 5

    2 Pages

  27. ADU 5

    2 Pages

  28. ABA 4

    2 Pages

  29. Foam Tester

    2 Pages

  30. PNR 12

    2 Pages

  31. BPA 5

    2 Pages

  32. Alex 500

    2 Pages

  33. OBA 2

    2 Pages

  34. TOST & TOO

    2 Pages

  35. OBA 1

    2 Pages

  36. DD 3

    2 Pages

  37. Grease Worker

    2 Pages

  38. DDA 3

    2 Pages