Electronic Measuring Instruments Catalog 2007 - Anritsu - #701

/ 789


catalogue search
P. 701
P. 702
P. 703
P. 704
P. 705
P. 706
P. 707
P. 708
P. 709
P. 710
P. 711
P. 712
P. 713
P. 714
P. 715
P. 716
P. 717
P. 718
P. 719
P. 720
P. 721
P. 722
P. 723
P. 724
P. 725
P. 726
P. 727
P. 728
P. 729
P. 730
P. 731
P. 732
P. 733
P. 734
P. 735
P. 736
P. 737
P. 738
P. 739
P. 740
P. 741
P. 742
P. 743
P. 744
P. 745
P. 746
P. 747
P. 748
P. 749
P. 750


See other catalogues for Anritsu

Text version of the page
SIGNAL GENERATORS
/inritsu
Ordering information
Please specify model/order number, name, and quantity when ordering.
Model/Order No.
Name
Model/Order No.
Name
Models
MG3690B/17
Delete Front Panel - Deletes the front panel for use in remote control applications where a front panel display and keyboard control are not needed. mmW Bias Output - Adds a rear panel BNC Twinax connector required to bias the 63850 millimeter wave source modules, sold separately (Not available with Option 7 or Option 15x).
0.1 Hz to 10 MHz Audio coverage - Uses a DDS for coverage down to approximately DC. When adding Option 22, the output power is derated by 2 dB. The frequency resolution below 10 MHz is 0.02 Hz. No modulation is available in the 0.1 Hz to 10 MHz band (Not available without Option 4 or 5). Pulse Modulation - External, via a rear panel BNC connector. For internal modulation capability, requires additionally Pulse Generator, Option 27. (This option comes in different versions, based on instrument configuration.)
Internal LF and Pulse Generators - Provides modulation waveforms for internal AM, FM, FM, and Pulse. (Not available without Option 12, 14, or 26.) Analog Modulation Suite - For ease of ordering and package pricing, this option bundles Options 12, 14, 26 and 27, offering internaland external AM, FM, FM, and Pulse Modulation. (This option comes in different versions, based on instrument configuration.) Low phase noise
Accessories
DC to 20 GHz, Ruggedized Type N female adapter for units with a K connector output Master/Slave interface cable set Transit case
IVI Driver, includes LabView® driver Aux I/O cable, 25 pin to BNC: Provides BNC access to V/GHz and Sequential Sync connections and other AUX I/O data lines
Millimeter wave accessories (MG3690B/18 recommended)
50-75 GHz V band Multiplier Source Module, WR-15 60-90 GHz E band Multiplier Source Module, WR-12 75-110 GHz W band Multiplier Source Module, WR-10
90-140 GHz F band Multiplier Source Module, WR-08 110-170 GHz D band Multiplier Source Module, WR-06 140-220 GHz G band Multiplier Source Module, WR-05 220-325 GHz H band Multiplier Source Module, WR-03
SMA male-male flexible cable, 90 cm (3 ft) (could be used to connect the MG3690B output to the module's
LO input)
Upgrades
Economical upgrades are available to upgrade any model to any higher performing model. Consult Anritsu for details.
MG3691B
2
- 10 GHz CW Generator
MG3692B
2
- 20 GHz CW Generator
MG3693B
2
- 30 GHz CW Generator
MG3694B
2
- 40 GHz CW Generator
MG3695B
2
- 50 GHz CW Generator
MG3696B
2
- 67 GHz CW Generator (operational to 70 GHz)
MG3690B/18
MG3690B/22
Options and accessories
Rack Mount with slides - Rack mount kit containing a set of track slides (90 degree tilt capability), mounting ears, and front panel handles to let the instrument be mounted in a standard 19-inch equipment rack. Rack Mount without slides - Modifies rack mounting hardware to install unit in a console that has mounting shelves. Includes mounting ears and front panel handles. Mechanical Step Attenuator - Adds a 10 dB/step attenuator. Rated RF output power is reduced. (This option comes in different versions, based on instrument configuration.)
Electronic Step Attenuator - Adds a 10 dB/step electronic attenuator with a 120 dB range for the MG3691B. Rated RF output power is reduced. Ultra Low Phase Noise, main band - Adds new modules to significantly reduce SSB phase noise. 10 MHz to 2.2 GHz RF coverage, Ultra-Low Phase Noise version - Uses a digital down converter to significantly reduce SSB phase noise. 10 MHz to 2 GHz RF coverage - Uses an analog down converter.
Analog Sweep Capability (limited to >500 MHz when used with Option 4)
IF Up-Conversion - Adds an internal 40 GHz mixer for
up-converting an IF signal. (Not available with
MG3695B, MG3696B, or with Option 18)
Power Monitor - Adds internal power measurement
capability (not available with Option 9).
Rear Panel Output - Moves the RF output connector to
the rear panel. (This option comes in different versions,
based on instrument configuration.)
User-Defined Modulation Waveform Software - External
software package provides the ability to download user-
defined waveforms into the memory of the internal
waveform generator, serially or via GPIB. External PC
and an instrument with LF Generator, Option 27, are
required. This external software package can only be
used with Option 10 enabled instruments.
Frequency and Phase Modulation - External, via a rear
panel BNC connector. For internal modulation capability,
requires additionally LF Generator, Option 27.
Amplitude Modulation - External, via a rear panel BNC
connector. For internal modulation capability, requires
additionally LF Generator, Option 27.
High Power - Adds high-power RF components to the
instrument to increase its output power level. (This
option comes in different versions, based on instrument
configuration.)
High Stability Time Base - Adds an ovenized, 10 MHz crystal oscillator as a high-stability time base.
MG3690B/1A
MG3690B/1B MG3690B/2X
MG3690B/2E
MG3690B/3 MG3690B/4
MG3690B/5 MG3690B/6 MG3690B/7
MG3690B/8
MG3690B/9X MG3690B/10
MG3690B/26X*
MG3690B/27
MG3690B/28X*
MG3690B/30
34RKNF50 ND36329
63270
2300-469 806-97
63850-15 63850-12 63850-10
63850-08 63850-06 63850-05 63850-03 806-121
MG3690B/12 MG3690B/14 MG3690B/15X
MG3690B/16
Pulse Modulation performance is controlled by United States Export Control regulations, >31.8 GHz. For Pulse Modulation solutions that do not require export licenses, please consult with your Anritsu sales representative.
ittp://www.anritsu.com 701

pageCatalog pdf di En 2012-05-19-13