|
catalogue search
|
You may also be interested in
Measuring device, Antenna, Signal generator, Network analyzer, Generator
Text version of the page
OPTICALMEASURINGINSTRUMENTSModelMU951301A MU951501A MU951001Aβ 1 1Warm-up time1 h (after optical output on) EnvironmentalOperating temperature/humidity: 0 to +50ΛC/ β€ 90% (no condensation); Storage Temperature: 25 to +71ΛCconditions Dimensions and mass41 (W) x 78 (H) x 335 (D) mm, β€ 700 g Note: Wavelengths in vacuumβ4: 15 min at constant temperature (at one point from +20 to +30ΛC)β1: Only one MU951001A can be installed into MT9812B.β5: 6 h at constant temperatureβ2: At CW, optical attenuation setting (0.00 dB), using SM fiber (ITU-T G.652)and FC-PC connectorβ6: 8 h at 0 to +50ΛCβ7: Specified connector for optical connector option supplied as standard ac-cessory. If connector not specified, FC (Option 37) supplied as standard.β3: When return loss seen from light source side is 40 dB min. ModelMU931311AMU931421AMU931422A?MU954501A Light Source (SLD)Optical elementSLD FiberSM fiber (ITU-T G.652) Wavelengthβ 1 1550 ±20 nm Spectral half-width β 1 β₯ 40 nm Optical output power β 1 3 ±1 dBm Time stability (short term) β 1, β 2, β 3 : β€ ±0.01 dBOptical output power stabilityTime stability (long term) β 1, β 2, β 4 : β€ ±0.1 dBTemperature stability β 1, β 2, β 5 : β€ ±0.5 dB Internal modulationFrequency: 270 Hz, 1 kHz, 2 kHz ±0.1%, Duty: 50% ±5%, Extinction ratio: β₯ 13 dB Optical output attenuation0.00 to 6.00 dB (0.01 dB steps), Accuracy: β€ ±0.5 dB (at 25ΛC when set to 6.00 dB) Laser safety mechanismJIS, IEC60825-1: Class 1, 21CFR1040.10: Class Ξ Optical connector β 6 FC, ST, DIN, HMS-10/A, SC (all PC type) Warm-up time1 h (after optical output on) Environmental conditionsOperating temperature/humidity: 0 to +50ΛC/ β€ 90% (no condensation)Storage Temperature: 40 to +71ΛC Dimensions and mass41 (W) x 78 (H) x 335 (D) mm, β€ 700 g Note: Wavelengths in vacuum, please contact us for 1310 nm SLD lightsource. β3: 15 min at constant temperatureβ4: 6 h at constant temperatureβ1: At CW, optical attenuation setting (0.00 dB), using SM fiber (ITU-T G.652)and FC-PC connectorβ5: 8 h at 0 to +50ΛCβ6: Specified connector for optical connector option supplied as standard ac-cessory. If connector not specified, FC (Option 37) supplied as standard.β2: When return loss seen from light source side is 40 dB min.?Optical sensorsElement InGaAs-PD Input type Fiber Applicable optical fiberSM (ITU-T G.652)9/125 to 62.5/125 ΅m (NA: β€ 0.29) Wavelength range 800 to 1600 nm 750 to 1700 nm Optical power CW: +10 to 110 dBm CW: +10 to 80 dBmmeasurement rangeβ 1 MOD: +7 to 90 dBm MOD: +7 to 90 dBm Noise level β 2 β€ 93 dBm β€ 73 dBm Polarization dependency β 3 β€ 0.02 dB β€ 0.05 dB Return loss β 3 β₯ 40 dB Optical power measure-ment uncertaintyReference conditions β 4 : ±2%, Operating conditions β 5 : ±3.5% Linearity β 6 ±0.05 dB (+10 to 0 dBm), ±0.01 dB ±0.3 pW (90 to 0 dBm)±0.05 dB (+10 to 0 dBm), ±0.01 dB ±30 pW (70 to 0 dBm) Calibration factor input 99.999 to +99.999 dB Wavelength sensitivity Measurement wavelength input in 0.01 nm units correction Zero set operation Automatic zero calibration Range select Auto, manual Modulated light reception CW/MOD selectable, MOD: 270 Hz, 1 kHz, 2 kHz Measurement interval β 7 1, 10, 20, 50, 100, 200, 500 ms, 1 s to 99 h 59 min 59 s Average setting Off, 2, 5, 10, 20, 50, 100, 200, 500, 1000 times Analog output β 8 Approx. +2 V Auto, manual Bandwidth select β 9 Manual setting:Auto, manual0.1, 1, 10, 100 Hz, 1, 10, 100 kHz Manual setting: 0.1, 1, 10, 100 Hz, 1, 10 kHz (CW mode only) (CW mode only) Optical connector β 10 FC-PC, ST, DIN, HMS-10/A, SC Environmental Operating temperature/humidity: 0 to +50ΛC/ β€ 90% (no condensation); storage: 40 to +71ΛCconditions Dimensions and mass 41 (W) x 78 (H) x 335 (D) mm, β€ 700 g 41 (W) x 78 (H) x 335 (D) mm, β€ 550 g http://www.anritsu.com 55 |