SPECTRUM ANALYZERS
/inritsu
Frequency
Reference level
Setting range
Log scale: -100 to +30 dBm, Linear scale: 224 uV to 7.07 V Unit
Log scale: dBm, dBuV, dBmV, V, dBuVemf, W
Linear scale: V Reference level accuracy:
±0.4 dB (-49.9 to 0 dBm), ±0.75 dB (-69.9 to -50 dBm, 0.1 to +30 dBm), ±1.5 dB (-80 to -70 dBm)
«After calibration, at 100 MHz, span: 1 MHz (when RF ATT, RBW, VBW, and sweep time set to AUTO) RBW switching uncertainty: ±0.3 dB (1 kHz to 1 MHz), ±0.4 dB (3 MHz) «After calibration, referenced to RBW: 3 kHz Input attenuator (RF ATT)
Setting range: 0 to 70 dB (10 dB steps)
«Manual settable, or automatically settable according to reference level
Switching uncertainty: ±0.3 dB (0 to 50 dB), ±1.0 dB (0 to 70 dB)
«After calibration, frequency: 100 MHz, referenced to RF ATT: 10 dB
Amplitude
Frequency response
Relative:
±1.5 dB (9.0 kHz to 3.2 GHz), ±1.0 dB (100 kHz to 3.2 GHz), ±1.5 dB (3.1 to 8.1 GHz), ±3.0 dB (8.0 to 14.3 GHz), ±4.0 dB (14.1 to 26.5 GHz), ±4.0 dB (26.2 to 40 GHz)
«After pre-selector tuning at microwave band, referenced to midpoint between highest and lowest frequency deviation in each band.
Absolute: ±5.0 dB (9 kHz to 40 GHz, RF ATT: 10 dB, referenced to 100 MHz) «After pre-selector tuning at microwave band
Waveform display
Scale (10 div.)
Log scale: 10, 5, 2, 1 dB/div
Linear scale: 10, 5, 2, 1%/div Linearity (after calibration)
Log scale: ±0.4 dB (0 to -20 dB, RBW: <1 MHz), ±1.0 dB (0 to -70 dB, RBW: <100 kHz), ±1.5 dB (0 to -85 dB, RBW: <3 kHz), ±2.5 dB (0 to -90 dB, RBW: <3 kHz)
Linear scale: ±4% (compared to reference level) Marker level resolution
Log scale: 0.01 dB, Linear scale: 0.02% of reference level
Spurious response
2nd harmonic distortion:
<-60 dBc (10 to 200 MHz, mixer input: -30 dBm), <-70 dBc (0.2 to 1.55 GHz, mixer input: -30 dBm), <-90 dBc or noise level (1.55 to 20 GHz, mixer input: -10 dBm) Two signal 3rd order intermodulation distortion: <-70 dBc (10 to 100 MHz), <-80 dBc (0.1 to 8.1 GHz), <-75 dBc or average noise level (8.1 to 26.5 GHz), <-75 dBc or average noise level (typical, 26.5 to 40 GHz) «Frequency difference of two signals: >50 kHz, mixer input: -30 dBm
Image response: <-65 dBc (<18 GHz), <-60 dBc (<22 GHz), <-55 dBc (<40 GHz)
Multiple/out of band response: <-70 dBc(<14 GHz), <-60 dBc (<26 GHz), <-55 dBc (<40 GHz)
1 dB gain compression
>-5 dBm (>100 MHz, at mixer input)
Sweep
Sweep time
Setting range: 20 ms to 1000 s (manually settable, or automatically settable according to span, RBW, and VBW) Accuracy: ±15% (20 ms to 100 s), ±25% (110 to 1000 s), ±1% (time domain sweep: digital zero span mode)
Sweep mode
Continuous, single
Time domain sweep mode
Analog zero span, digital zero span
Zero sweep
Sweeps only in frequency range indicated by zone marker.
Tracking sweep
Sweeps while tracing peak points within zone marker (zone sweep also possible).
Functions
Number of data points
501
Detection mode
NORMAL: Simultaneously displays max. and min. points between sample points. POS PEAK: Displays max. point between sample points. NEG PEAK: Displays min. point between sample points. SAMPLE: Displays momentary value at sample points. Detection mode switching uncertainty: ±0.5 dB (at reference level)
Display
Color TFT-LCD, Size: 14 cm, Number of colors: 17 (RGB, each 64-scale settable), Intensity adjustment: 5 steps settable
Display functions
Trace A: Displays frequency spectrum. Trace B: Displays frequency spectrum.
Trace Time: Displays time domain waveform at center frequency.
Trace A/B: Displays Trace A and Trace B simultaneously. Simultaneous sweep of same frequency, alternate sweep of independent frequencies.
Trace A/BG: Displays frequency region to be observed (background) and object band (foreground) selected from
background with zone marker simultaneously. Trace A/Time: Displays frequency spectrum, and time domain waveform at center frequency simultaneously. Trace move/calculation: A -- B, B -- A, A —- B, A + B -- A, A — B -- A, A — B + DL -- A
Storage functions
NORMAL, VIEW, MAX HOLD, MIN HOLD, AVERAGE, CUMULATIVE, OVER WRITE
FM demodulation waveform display function
Demodulation range: 2, 5, 10, 20, 50, 100, 200 kHz/div Marker display
Accuracy: ±5% of full scale (referenced to center frequency, DC-coupled, RBW: 3 MHz, VBW: 1 Hz, CW) Demodulation frequency response: DC (50 Hz at AC-coupled) to 100 kHz (range: <20 kHz/div, VBW: off, at 3 dB bandwidth)
DC (50 Hz at AC-coupled) to 500 kHz (range: <50 kHz/div, VBW: off, at 3 dB bandwidth) «RBW: >1 kHz to 3 MHz usable
Input connector
K-J, 50 n
Auxiliary signal input and output
IF OUTPUT: -10 dBm (typical, 100 MHz, upper edge of scale, 50 n terminated), 10.69 MHz, BNC connector
VIDEO OUTPUT (Y): 0 to 0.5 V ± 0.1 V (typical, from lower edge to upper edge at 10 dB/div)
0 to 0.4 V± 0.1 V (typical, from lower edge to upper edge at 10%/div)
BNC connector «75 n terminated at 100 MHz input COMPOSITE OUTPUT: For NTSC, 1 Vp-p (75 n terminated), BNC connector EXT REF INPUT: 10 MHz ±10 Hz, -10 to +2 dBm (50 n terminated), BNC connector
REF BUFFERED OUTPUT: >0 dBm (50 n terminated), BNC connector
1ST LOCAL OUTPUT: 4 to 7 GHz, >+8 dBm, 50 n, SMA-J connector
Continued on next page
http://www.anritsu.com 461

pageCatalog pdf di En 2012-02-07-14