OPTICAL MEASURING INSTRUMENTS
/inritsu
Selection guide
Application
Model
Optical power
Light source wavelength
Loss
Optical identification
Optical return loss measurement
Fiber evaluation
Laser diode testing
Others
Remarks
Low level
Medium/high level
Spectrum
Wavelength
High-loss
High accuracy
Loss-wavelength
Identification
Loss
Fault location
Splice loss
Optical Power Meter
ML9001A
V
V
V
V
V
V
-100 to +10 dBm
ML9002A
V
V
V
V
-70 to +20 dBm
Optical Test Set
MT9810B
V
V
V
V
V
V
V
V
V
0.75 to 1.7 urn
Multi Channel Box
MT9812B
V
V
V
V
V
V
V
0.75 to 1.7 um
Optical Loss Test Set
MS9020D
V
V
V
V
V
V
0.85/1.3/1.55 um
Optical Spectrum Analyzer
MS9710B
V
V
V
V
V
V
V
V
0.6 to 1.75 um
MS9710C
V
V
V
V
V
V
V
V
0.6 to 1.75 um
MS9780A
V
V
V
V
V
V
V
V
0.6 to 1.75 um
WDM Tester
MS9715A
V
V
V
V
V
1.527 to 1.567 um
Optical Time Domain Reflectometer
MW9076 series
V
V
V
V
V
V
V
1.31/1.45/1.55/1.625 um (SM), 0.85/1.3 um (Gl)
OTDR Module
MW9077A/A1
V
V
V
V
V
V
1.31 um (SM)/1.55 um (SM)
ACCESS Master
MT9080 series
V
V
V
V
V
V
V
1.31/1.55/1.65 um (SM)
Optical Attenuator
MN938A
V
0.85/1.3 um
MN9605C
V
1.31/1.55 um
MN95D
V
1.3 um
Optical Channel Selector
MN9662A/9664A/9672A/9674A
V
1.2 to 1.65 um
Optical Directional Coupler
MN9604C/D
V
V
1.25 to 1.60 um
Bare Fiber Connector
MA9014A, MP922B
V
Fiber Adapter
MA9013A
V
Optical Accessories
Optical fiber cord, adapter, dummy fiber, optical fiber cutter, jacket stripper, mode scrambler
V
Optical connector options for Anritsu optical meas
A variety of optical connectors are used with optical fibers worldwide. Specify the option number, model name, and number of the optical connector from the table below according to the type of optical con­nector you use. If no specification is made, an FC-type connector will be supplied.
For combinations marked with "V" symbols in the table, the required instrument can be supplied according to the order. For connectors without "V" symbols or which do not appear in the table, consult your sales representative. For measuring equipment with more than one
ng instruments
control panel, specify only the connector connected to the measured fiber. Be sure to consult us before ordering, particularly for optical connectors for single-mode fibers, to avoid trouble with connectors not fitting.
Optical connectors may be designed for either flat-polished or PC-polished ends. Some measuring instruments use connectors only for PC-polished ends; consult the literature on the instrument before specifying the connector option.
ittp://www.anritsu.com 26

pageCatalog pdf di En 2012-05-21-27