PULSE PATTERN GENERATORS/ERROR DETECTORS

ERROR DETECTOR

MP1776A

100 MHz to 12.5 GHz

Supports Measurement for up to 50 Gbit/s System (Installed with 4 Channels)

MP1776A is an error detector housing four error detectors that canmeasure error up to 12.5 Gbit/s. It has four-channels independent measurement mode, two-channels or four-channels combined mea- surement mode and be used for development, manufacturing and maintenance of transmission systems and modules from 12.5 Gbit/s to maximum 50 Gbit/s.

Features ?

Max. 4-channels in one box

?

Independent measurement of 4-channels

?

PRBS patterns from 2

7

– 1 to 2

31

– 1

?

Max. 32 Mbit programmable pattern at 4-channels combined mode (corresponding six frames of STM-256/STS-768)

?

Burst data BER measurement for optical circulating loop test

?

Good operability by GUI

Specifications ?

Display 4-channels measurement results on screen

?

MP1776A (main frame), MU177601B (12.5 Gbit/s Error Detector)

Operating frequency100 MHz to 12.5 GHz PRBS pattern: 2
n – 1 (n: 7, 9, 11, 15, 20, 23, 31)Zero substitution pattern: 2
n (n: 7, 9, 11, 15), consecutive zero-pattern can be inserted up to pattern length – 1Programmable data Measurement patternIndependent: 2 to 8,388,608 bits2-channels combined: 4 to 16,777,216 bits4-channels combined: 8 to 33,554,432 bitsLogic inversion: Positive/negative switching possible Measurement modeIndependent
∗ 1 , 2-channels combined
∗ 2 , 4-channels combined
∗ 3 Synchronization methodNormal, frame Error detection modeInsertion, omission, total Error ratio: 0.0000 x 10
–16 to 1.0000 x 10
Error count: 0 to 9,999,999, 1.0000 x 10
7 to 9.9999 x 10
16 Measurement itemsClock frequency: 0.1 to 12.5 GHz (independent), 0.2 to 25 GHz (2-channels combined), 0.4 to 50 GHz (4-channels combined)

∗

Resolution: 1 kHz, accuracy: 10 ppm ±1 kHz Sync threshold valueInternal, 10
–n (n: 2, 3, 4, 5, 6, 7, 8) Auto search functionSupported Input waveform: NRZ Input amplitude: 0.5 to 2.0 Vp-p Threshold voltage: –3.000 to +1.750 V (1 mV step)Data inputTermination condition: GND/–2.0 VInput impedance: 50 Ω Connector: APC-3.5Number of input: 1 (MU177601B 12.5 Gbit/s Error Detector Unit) Input level: 0.5 to 2.0 Vp-pInput waveform: Square wave only (<0.5 GHz, Duty: 50%), Sine or square wave ( ≥ 0.5 GHz, duty: 50%)Clock delay: ±500 ps (1 ps step)Clock inputPolarity inversion: POS/NEG inversion selectableInput impedance: 50 Ω Connector: APC-3.5Number of input: 1 (MU177601B 12.5 Gbit/s Error Detector Unit, up to 4 channel can be added.) Continued on next page

http://www.anritsu.com 176


pageCatalog pdf di En 2012-05-20-15