LIFEGARD II
The Most Powerful Non-Invasive Monitor in its Class
m
The Analogic LIFEGARD® II is the most pow­erful, non-invasive monitor in its class avail­able today This versatile monitor measures five vital signs and can be used anywhere in the hospital or office environment
• Up To 5 Non-invasive Measurements -ECG (HR), RESP, SpO2, NIBP, or TEMP
• 4-hour Typical Battery Life for Prolonged Transport Monitoring
• User Interface that Enhances Simplicity of Use and Data Presentation
• Large Color Display - Exceptional Data Visualization
• Network Ready for Connection to LIFEGARD Vue Central Alarm Annunciation System
• 3 or 5 Lead ECG with Support for 2-Lead Simultaneous Displaywhen Using 5 Leads
r-
CO
Specifications
ECG Performance
Leads: 3 or 5 leads, user selectable Heart Rate Range: 20 to 250 bpm Heart Rate Accuracy: ± 1 bpm or ±1% Bandwidth - Normal Monitoring: 0.5 Hz to 40 Hz Bandwidth-ExtendedLow FrequencyRange (user selectable): 0.05 Hz to 40 Hz Display Sweep Speeds: 12.5,25,50 mm/sec ECG Size (Sensitivity): 0.5,1,2,4 mV/cm Lead-Off Detection with display indicator Pacemaker Detection Mode: Indicator on waveform display, user selectable Standards: ANSI/AAMIEC13 Differential Input Impedance: >5MQ Common Mode Rejection Ratio:
>90dBat50or60Hz Input Dynamic Range: ± 5 mV AC, ± 300 mV DC Defibrillation Artifact Recovery Time:
< 5 sec conforming to AAMIEC13
Respiration Performance
Range: 3 to 150 breaths per minute
Accuracy: ± 3 breaths per minute
Display Sweep Speeds: 6.25,12.5,25 mm/sec
NIBP Performance
Blood Pressure Accuracy: Meets performance standards
of ANSI/AAMI SP10(1) Technique: Oscillometric Pulse Rate Range: 40 to 200 bpm Maximum Cuff Pressure: Safety Limited to 300 mmHg Pulse Rate Accuracy: ±2 bpm or ±2% Initial Cuff Inflation is User Adjustable; Factory Default:
160 mmHg (adult mode); 120 mmHg (pediatric mode) Subsequent Cuff Inflation: Previous Systolic ±30 mmHg
Blood Pressure Measurement Range
Systolic: 40 to 250 mmHg Diastolic: 20 to 200 mmHg Mean Arterial Pressure: 27 to 220 mmHg Measurement Modes
Auto: Automatic measurements at intervals of 1, 3,5, 10, 30, 60, and 90 minutes Manual: Single measurement initiated by Start/Stop button
STAT: Series of consecutive measurements for 5 minutes
SpO2 Performance
Nellcor® OXIMAX™ Technology % Saturation Range: 1% to 100% Pulse Rate Range: 30 to 250 bpm SpO2 Accuracy: 70% to 100% ± 3 digits
with DS100A sensor Pulse Rate Accuracy: ± 3 bpm
Temperature Performance
Range: 15°C to 45°C (59°F to 113°F)
Accuracy: ± 0.1°C (0.18°F)
Compatible with YSI 401 and 409 Temperature
Probes