Blowers - AMETEK Technical & Industrial products - #52

/ 128


catalogue search
P. 51
P. 52
P. 53
P. 54
P. 55
P. 56
P. 57
P. 58
P. 59
P. 60
P. 61
P. 62
P. 63
P. 64
P. 65
P. 66
P. 67
P. 68
P. 69
P. 70
P. 71
P. 72
P. 73
P. 74
P. 75
P. 76
P. 77
P. 78
P. 79
P. 80
P. 81
P. 82
P. 83
P. 84
P. 85
P. 86
P. 87
P. 88
P. 89
P. 90
P. 91
P. 92
P. 93
P. 94
P. 95
P. 96
P. 97
P. 98
P. 99
P. 100


See other catalogues for AMETEK Technical & Industrial products

Text version of the page
VMETEK
TECHNICAL & INDUSTRIAL PRODUCTS
5.7" (145mm) BLDC Thru Flow Blower
400 Watt, 240 Volt Standard Flow
.229±.006 .37
(3) 0 (5.82±. 1 5) HO LES (9.4) MIN.
DEEP EQUALLY SPACED AS SHOWN ON A 0 4.00 I BOLT CIRCLE.
0 (101.6)
0.034/(0.86) A MM
INCH (MM)
1.14±.05 (28.96±1.27)
90e (2X)
(3X) 0 (12419) -, +3° MAX. SPEED DFT./SIDE CONTROL
ACCESS FOR MECHANICALLY ADJUSTED SPEED
CONTROL
.168±.003 (3) 0 (4.27±.07) HOLES THRU. LOCATED AS SHOWN ON A
I 0
650H BOLT CIRCLE.
(165.1)
.168±.003-(1) 0 (4. 27± .07) HOLES THRU.
LOCATED AS SHOWN ON A
>|0.034/(0.86) AM
6.400 I BOLT CIRCLE.
POST HEADER
SEE DETAIL
"E"OR"M"
I 0
(162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING
OF EARTHING.
№10.034/(0.86) AMPI ®
Blower Data
Unit of Measure
Part Number
Standard Flow
117629 E*
117630 E*
Stages
1
2
Vacuum, Maximum (Sealed Vacuum)
in. H2O
28
47
mBar
69
117
Pressure, Maximum (Sealed Pressure)
in. H2O
31
50
mBar
77
124
Flow Rate, Maximum (Open Flow)
CFM
67
65
m3/hr
114
110
Length
(Dimension "I" above)
inches
.69
1.60
mm
17.53
40.64
Length
(Dimension "L" above)
inches
3.21
4.12
mm
81.53
104.65
* These part numbers are available through AMETEK Technical & Industrial Products' distributors.
NOTES:
• Nominal input Voltage: 240 Volts AC RMS ±10%, 50160Hz.
• Input Current 5 amps AC RMS maximum.
• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C
• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
• Optional: IntelliGen™ controller available for customized performance.
• Maximum Approximate Weight: 6 lbs.
|52J
WF-RF RIR DIM RRIIRHI FRR'

pageCatalog pdf di En 2012-05-21-27