Model ACT
steel construction for use with most media types. An
economical non isolated brass transducer, used for
clean, dry media is optional.
The ACT offers premium performance and versatility of
use for many applications, both for the general industrial
end user and original equipment manufacturers (OEM).
It combines precision along with the durability to operate
under diffi cult environmental conditions.
The ACT is manufactured in the United States under
ISO 9001:2000 control.
Features
Digitally C • ompensated - Low total accuracy
errors for interchangeability and high precision
measurements.
• Multiple Pressure Port Options - Ease of installation
and attachment and no adapters required.
• Numerous Weatherproof Electrical Connection
Options - Quick hook-up and remote applications.
• Stainless Steel Construction and Wetted Materials -
Resists the corrosive effects of caustic medias or
washdowns and compatible with a variety of media.
• 0.2% Typical Accuracy - Offers superior accuracy
to competitive models and can be used on critical
applications.
• Factory Calibrated for Pressure and Temperature -
No need for fi eld calibration. Plug and play reliability.
• Wide Pressure Ranges and Types (PSIG, PSIA,
PSIS, Compound) - Can be used in a variety of
applications. PSIA and compound units can be used
for vacuum to absolute or atmospheric pressures.
• Rugged, Compact Design - Easy to package
or install.
• RFI/EMI Protection - For use in high noise
environments.
• Reverse Polarity Protection - Installation safety
and not damaged by reverse wiring.
• Custom Designs Available - Adaptable to special
needs.
Description
The Model ACT builds upon the successful DCT product
line by offering an Analog Compensated Transducer
with 0 to 100mV output. The Model ACT is ideal for
OEM customers that want non-digital outputs into their
control system. The Model ACT is available in brass and
stainless steel.
This product is offered in a variety of mounting options,
stainless steel or brass construction, and numerous
pressure ranges. It is fully compensated for the effects
of pressure and temperature change and calibrated
to produce industry standard electrical outputs. The
ACT accepts both unregulated and regulated excitation
voltages and provides output signals such as 0 to 100mV.
The ACT Transducer is offered in pressure ranges from
1 psi up to and including 3000 psi.
The Model ACT is extremely accurate, less than
±0.3% full scale over pressure and less than ±1.0%
full scale over a wide compensated temperature range
(±0.5% full scale optional). The design incorporates a
stainless steel isolation diaphragm and 316 stainless
Analog Compensated Pressure Transducer
|
|