temperature

• 12-month accuracy to ±0.04°C / 0.07°F• Temperature range -90° to 650°C / -130° to 1202°F • Stability to ±0.01°C / 0.018°F • 14 different models • MVI stability circuitry • 100% automatic calibration • RS232 interface and JOFRACAL calibration software• Input for external reference sensor• Input for sensor-under-test • Timesaving auto-stepping and temperature switch test functions• Interchangeable inserts including multi-hole designs• Active dual-zone

JOFRA ATC Advanced Temperature calibrator

A complete on-site test laboratory that brings temperature calibration to a new level

The ATC series offers a wide temperature calibration range (-90 to 650ËšC) and improved stability (+ 0.01ËšC for most models) for marine calibration. It utilizes innovative dual-zone heating technology for precision calibration of sensors. Independent heating control allows the lower zone to ensure optimum heat dissipation throughout the entire calibration zone, while the upper zone compensates for heat loss from the sensor-under-test and the open top. This design also eliminates the need for insulation of the sensors-under-test and allows calibration of liquid-filled and other mechanical sensors. Calibration of even more sensors Two models of the ATC series (ATC-140 and ATC-250) can be used both as dry-block calibrators and as liquid calibration baths with a magnetic stirrer. The liquid bath and the dry-block diameter of 63.5 mm (2.5 in) are twice the size of any other JOFRA dry-block. With these options, it is now possible to calibrate even more temperature sensors at the same time and to calibrate large as well as odd sizes and shapes of sensors, which were not possible to calibrate in the existing range. Calibration at very low temperatures The JOFRA ATC-125 ultra cooler features a unique technology for optimum performance and superior temperature homogeneity throughout the block at very low temperatures. The ATC-125 has a performance equivalent to a liquid temperature bath and features the widest temperature range for any cooling dry-block on the market today offering a temperature range from 125°C down to -90°C! The unique free piston stirling cooler technology sets new standards for optimum temperature calibrations in frozen and deep frozen applicatons. Especially within the marine industry, this is relevant in product and gas tankers. Find more information in specification sheet SS-CP-2282 at www.jofra.com (ATC-125 ultra cooler) Find more information in specification sheet SS-CP-2284 at www.jofra.com (ATC 140/250 liquid bath and large insert) Find more information in specification sheet SS-CP-2285 at www.jofra.com (ATC-156/157/320/650) Engine rooms - testing the temperature in exhaust gas Savings The exhaust gas temperature is a very important factor. If the temperature is too low, too little fuel will be let into the cylinder, and if the temperature is too high, too much fuel will be let into the cylinder.Often a range of ±10°C (50°F) is allowed, before the alarm is activated. However, if calibration is performed more often, this range could be reduced and a more economical combustion could be achieved. Engine rooms - testing the temperature in exhaust gas Application On each cylinder, a thermometer has been placed close to the exhaust gas outlet to measure the temperature of the exhaust gas. This thermometer breaks very often due to the impact from the exhaust gas. As a consequence the temperature indication is often inaccurate. Thermometers most frequently have a scale from 350 to 450°C (662 to 842°F). www.jofra.com 3
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8