PATENTED
Figure 1 SO2-BF Schematic Diagram
All dimensions in millimetres (± 0.1mm)
Bottom View
Side View
Top View
PERFORMANCE Sensitivity
Response time Zero current Resolution Range Linearity Overgas range
nA/ppm in 20ppm SO2 300 to 440
tgo (s) from zero to 20ppm SO2 < 30
ppm equivalent in zero air < ± 0.5
RMS noise (ppm equivalent) < 0.1
ppm limit of performance warranty 100 ppm error at full scale, linear at zero and 20ppm SO2 < ± 2
maximum ppm for stable response to gas pulse 500
LIFETIME Zero drift ppm equivalent change/year in lab air nd
Sensitivity drift % change/month in lab air, twice monthly test < 2
Operating life months until 80% original signal (24 month warranted) > 24
ENVIRONMENTAL Sensitivity @ -20C
% (output @ -20C/output @ 20C) @ 20ppm
84 to 94
Sensitivity @ 50C
% (output @ 50C/output @ 20C) @ 20ppm
96 to 102
Zero @ -20C
ppm equivalent change from 20C
< ± 0.4
Zero @ 50C
ppm equivalent change from 20C
< ± 3
CROSS
Filter capacity
ppmhrs
H2S
450
SENSITIVITY
NO sensitivity
% measured gas @ 50ppm
NO
< -3
NO2 sensitivity
% measured gas @ 10ppm
NO2
< -120
Cl2 sensitivity
% measured gas @ 10ppm
Cl2
< -50
H2 sensitivity
% measured gas @ 400ppm
H2
< 0.1
CO sensitivity
% measured gas @ 400ppm
CO
< 1
C2H4 sensitivity
% measured gas @ 400ppm
C2H4
< 40
NH3 sensitivity
% measured gas @ 20ppm
< 0.1
KEY
Temperature range
C
-30 to 50
SPECIFICATIONS Pressure range
kPa
80 to 120
Humidity range
% rh continuous (see note below)
15 to 90
Storage period
months @ 3 to 20C (stored in sealed pot)
6
Load Resistor
Q (recommended)
10 to 47
Weight
g
< 13
Note: Above 85% rh and 40oC a miximum continuous exposure period of 10 days is warranted. Where such exposure occurs the sensor will recover normal electrolyte volumes when allowed to rest at lower % rh and temperature levels for several days.
NOTE: all sensors tested and stored at ambient environments unless otherwise stated. As applications of use are outside our control, the Information provided Is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.
Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley. CM77 7AA. UK Telephone: +44 (0) 1376 556 700 Fax: +44 (0) 1371 335 899 E-mail: sensors@alphasense.com Website: www.alphasense.com