| | | CH-A3 Performance Data | | |
| | | |
| | | Figure 2 Sensitivity Temperature Depend | | |
| | | |
| | | Figure 2 shows the variation in sensitivity caused by changes in temperature. Data are taken from a typical batch of sensors and the mean and ±95% confidence intervals are shown. | | |
| | | |
| | | Figure 3 shows the non-linearity from 0 to 5% methane (volume]. Sensor non-linearity at 100% LEL Is less than4%. Data are taken from a typical batch of sensors and the mean and ±95% confidence intervals are shown. | | |
| | | |
| | | Sensitivity remains nearly constant over small voltage variations. Accurate setting of the pellistor voltage is not necessary. | | |
| | | |
| | | Bridge voilage (V) | | |
| | | |