Combustible LEL (Minature) Sensor - Alphasense - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for Alphasense

Text version of the page
Figure 2 Voltage Sensitivity
120
Figure 2 shows the variation in sensitivity caused by changes in pellistor voltage. The pellistor is relatively insensitive to small voltage variations, avoiding individual bridge voltage adjustments.
Data are taken from a typical batch of sensors and the mean and ±95% confidence intervals are shown.
> ™ i
co
TO
>
'en
eu «S
_>>
>
'in
eu en
c
0
80
60
40
20
0s
0
2.4 2.6 2.8
Bridge voltage (V)
Figure 3 Zero Temperature Dependence
Figure 3 shows the variation in zero output caused by changes in temperature, expressed as % methane. Zero shifts less than ± 0.1% LEL from -30oC to +50oC.
0
0)
LU
_l
I -3< ro
e
N
Temperature (oC)
Figure 4 HMDS Poisoning
1.4
When exposed to 42ppm HMDS in 25% LEL methane, sensitivity loss is slower than equivalent pellistors.
1.2
I
C
-° cn
a
ut
0.6
tp ut
O
0.4
0.2
0
0
2000
4000 5000
Time (seconds)
6000
1000
3000
7000
8000
9000
For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. For Application Notes visit "www.alphasense.com".
In the interest of continued product improvement, we reserve the right to change design features and specifications without prior notification. The data contained in this document is for guidance only. Alphasense Ltd accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it ( ©ALPHASENSE LTD ) Doc. Ref. TDS/CHD3/Issue 2