CO-BX Carbon Monoxide Sensors - Alphasense - #1

/ 2


catalogue search
CO-BX Carbon Monoxide Sensors - Alphasense
P. 01
CO-BX Carbon Monoxide Sensors - Alphasense
P. 02
Pages:
CO-BX Carbon Monoxide Sensors - Alphasense


See other catalogues for Alphasense

Text version of the page
on Monoxide Sensor
gen Cross Sensitivity
PATENTED
Figure 1 CO-B
S^n^ng area
Oí not Ofcííiirg
All dimensions in millimetres (± 0.1 mm)
Bottom View
Top View
Side View
PERFORMANCE Sensitivity
Response time Zero current Resolution Range Linearity Overgas range
nA/ppm in 400ppm CO 70 to 120
t9o (s) from zero to 400ppm CO < 40
ppm equivalent in zero air < ± 1.5
RMS noise (ppm equivalent) < 1
ppm limit of performance warranty 2,000 ppm CO error at full scale, linear at zero, 400ppm CO < ± 5
maximum ppm for stable response to gas pulse 5,000
LIFETIME Zero drift ppm equivalent change/year in lab air < 0.1
Sensitivity drift % change/month in lab air, monthly test < 1
Operating life months until 80% original signal (24 month warranted) > 24
ENVIRONMENTAL
Sensitivity @ -20C
% (output
@ -20C/output @ 20C) @ 400ppm CO
30 to 60
Sensitivity @ 0C
% (output @ 0C/output @ 20C) @ 400ppm CO
65 to 80
Sensitivity @ 50C
% (output @ 50C/output @ 20C) @ 400ppm CO
110 to 135
Zero @ -20C
ppm equivalent change from20C
± 4
Zero @ 0C
ppm equivalent change from 20C
± 1
Zero @ 50C
ppm equivalent change from 20°C
0 to -6
CROSS
Filter capacity
ppmhrs
H2S
160,000
SENSITIVITY
Filter capacity
ppmhrs
NO
120,000
Filter capacity
ppmhrs
NO2
120,000
Filter capacity
ppmhrs
SO2
160,000
SO2 sensitivity
% measured gas @ 20ppm
SO2
< 0.1
NO sensitivity
% measured gas @ 50ppm
NO
nd
NO2 sensitivity
% measured gas @ 10ppm
NO2
< 1
Cl2 sensitivity
% measured gas @ 10ppm
Cl2
nd
H2 sensitivity
% measured gas @ 400ppm
H2 at 20oC
< 5
C2H4 sensitivity
% measured gas @ 400ppm
C2H4
< 10
H2S sensitivity
% measured gas @ 20ppm
H2S
< 0.1
NH3 sensitivity
% measured gas @ 20ppm
< 0.1
KEY
Temperature range
°C
-30 to 50
SPECIFICATIONS Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20C (stored in sealed pot)
6
Weight
g
< 13
Important. The CO-BX must be operated with a 0 Volt bias between Reference & Working electrodes. Failure to comply with this requirement will result in a loss of its low Hydrogen cross sensitivity performance.
NOTE: all sensors are tested at ambient environmental conditions, with 10 ohm load resistor, unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.
Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley. CM77 7AA. UK Telephone: +44 (0) 1376 556 700 Fax: +44 (0) 1376 335 899 E-mail: sensors@alphasense.com Website: www.alphasense.com

pageCatalog pdf di En 2012-02-07-15