| | | Carbon Monoxid High Concentrata | | |
| | | ens< | | |
| | | |
| | | |
| | | PATENTED | | |
| | | Figure 1 CO-AE Schematic Diagram 010 ■ 13.5 PCD | | |
| | | |
| | | 020.2 including label | | |
| | | Worker | | |
| | | |
| | | |
| | | |
| | | c 0 | | |
| | | Counter | | |
| | | Reference- | | |
| | | CARBON MOK CO-AE 123451 | | |
| | | |
| | | |
| | | |
| | | Sensing area Do not obscure | | |
| | | 0.7 recess | | |
| | | |
| | | |
| | | All dimensions in millimetres (± 0.1mm) Bottom View | | |
| | | Side View | | |
| | | Top View | | |
| | | |
| | | |
| | | | | | | | | | | | PERFORMANCE | Sensitivity | nA/ppm in 2,000ppm CO | 12 to 20 | | | | | Response time | t9o (s) from zero to 2,000ppm CO | < 75 | | | | | Zero current | ppm equivalent in zero air | < ± 20 | | | | | Resolution | RMS noise (ppm equivalent) | < 5 | | | | | Range | ppm CO limit of performance warranty | 10,000 | | | | | Linearity | ppm error at full scale, linear at zero and 2000ppm CO | <0 to 500 | | | | | Overgas range | maximum ppm for stable response to gas pulse | 100,000 | | | | LIFETIME | Zero drift | ppm equivalent change/year in lab air | nd | | | | | Sensitivity drift | % change/month in lab air, monthly test | nd | | | | | Operating life | months until 80% original signal (24 month warranted) | > 24 | | | | ENVIRONMENTAL Sensitivity @ -20C | % (output @ -20C/output @ 20C) @ 400ppm CO | 77 to 93 | | | | | Sensitivity @ 50C | % (output @ 50°C/output @ 20C) @ 400ppm CO | 97 to 110 | | | | | Zero @ -20C | ppm equivalent change from 20C | ±2 | | | | | Zero @ 50C | ppm equivalent change from 20C | -2 to +5 | | | | CROSS | Filter capacity | ppm>hours H2S | 3,000,000 | | | | SENSITIVITY | Filter capacity | ppm-hours NO2 | 8,000,000 | | | | | Filter capacity | ppm-hours NO | 2,000,000 | | | | | Filter capacity | ppm-hours SO2 | 4,000,000 | | | | | SO2 sensitivity | % measured gas @ 20ppm SO2 | < 0.1 | | | | | NO sensitivity | % measured gas @ 50ppm NO | nd | | | | | NO2 sensitivity | % measured gas @ 10ppm NO2 | < 1 | | | | | CI2 sensitivity | % measured gas @ 10ppm | nd | | | | | H2 sensitivity | % measured gas @ 400ppm H2 at 20oC | <75 | | | | | C2H4 sensitivity | % measured gas @ 400ppm C2H4 | < 60 | | | | | H2S sensitivity | % measured gas @ 20ppm H2S | < 0.1 | | | | KEY | Temperature range | C | -30 to 50 | | | | SPECIFICATIONS Pressure range | kPa | 80 to 120 | | | | | Humidity range | % rh continuous | 15 to 90 | | | | | Storage period | months @ 3 to 20C (stored in sealed pot) | 6 | | | | | Load resistor | w (recommended) | 10 to 47 | | | | | Weight | g | < 6 | | | | | | | | | | | |
| | | 0 | | |
| | | |
| | | |
| | | NOTE: all sensors are tested at ambient environmental conditions, with 10 ohm load resistor, unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements. | | |
| | | |
| | | Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley. CM77 7AA. UK Telephone: +44 (0) 1376 556 700 Fax: +44 (0) 1376 335 899 E-mail: sensors@alphasense.com Website: www.alphasense.com | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |