Electronics Module: • Enter and store GC Methods via Color Touch Screen Actual and set-point display of ail GC parameters Safety Limits on ail user entered parameters Oven Température Programs (OTP) with Multiple Ramps Pressure Programs for Carrier Gases with Multiple Ramps Timeline for sequencing Relays and Valve Detector Control of ail Parameters on one page • Up to 2 Electronic Pressure Controllers (EPC's): Atmospheric Pressure & Température Compensation EPC Pressure Control with 0.1 kPa set point resolution • Plug and Play GC Control, Oven, and Detector Board Microprocessor Controlled Proprietary Digital Signal Processing • Digital Signal Outputs for each Detector • Universal voltage input (85 - 240 Vac) with line filter and breaker. • 7 amps at 48Vdc total power consumption • Optional inverter for DC Voltage Input Oven Module: • Ambient to 325 °C Column Oven(s) Up to 80 °C per/min Oven Ramp Fast Cooldown 325 °C to50°C <4min 200 watt Heater Elément Multiple Température Ramps with 0.1 °C set-point resolution 12.5 x 10.5 x 12.5 cm area for Capillary Columns • Optional Single Electronic Gas Sample Valve Injectors: • 1 or 2 Installée! • Split/Splitless modified and non-heated for Gas Samples • Cool On-column Injector • Multiple Pressure Ramps with 0.1 kPa set-point resolution • Up to 2 control Solenoids Detectors: •1 Installée! • 300°C Température Limit with 0.1 °C set-point resolution • 24-bit Digital Outputs for the detector via USB • EPC Pressure Control with 0.1 kPa set-point resolution Available Detectors: FID - Flame lonization Detector (100 pg détection limit) PID - Photoionization Detector (10 pg détection limit) TCD - Thermal Conductivity Detector (1 ppm détection limit) HID - Hélium lonization Detector (100 pg détection limit) NPD - Nitrogen Phosphorus Detector (20 pg détection limit) TID - Thermoionic Detector (20 pg détection limit) ECD - Electron Capture Detector (0.1 pg détection limit) Data Communications: • Bi-directional communication with popular Data Systems •Digital SignalOutputvia USB Network Connectivity: • Enterprise Compatible Network GC running Windows XPe • On Board ETX Computer for GC Control and Data Acquisition • Ethernet Connection using Windows Network Protocol • Remote Control of GC and Data Acquisition over LAN/WAN/VPN 760 S Rochester Ave., Suite E Ontario, CA 91761-8181 www.dps-instruments.com DP S Tel: 1-877-605-2555 Fax: 1-909-605-1183 Outside the USA: 1-909-605-1140 Instruments. Inc.

pageCatalog pdf di En 2012-05-21-27