DECADE - LC/ EC Workstation - Alpha MOS - #1

/ 2


catalogue search
DECADE - LC/ EC Workstation - Alpha MOS
P. 01
DECADE - LC/ EC Workstation - Alpha MOS
P. 02
Pages:
DECADE - LC/ EC Workstation - Alpha MOS


See other catalogues for Alpha MOS

Text version of the page
The Next DECADE Ahead! DECADE II LC-EC Workstation DECADE II LC-EC Workstation Antec Leyden bv Industrieweg 12, 2382 NV Zoeterwoude, The Netherlands Tel: + 31 71 581 3333 Fax: + 31 71 581 3334 mailbox@antecleyden.com www.antecleyden.com Ranges 10 pA – 200 ìA in 1, 2, 5 steps Filter (cut off) Advanced Digital Filter, 0.5 - 0.001 Hz, 1, 2, 5 steps Noise better than 2 pA with a dummy cell (load of 300 MÙ and 0.5 ìF), filter off, Ec +800mV and temperature of 30°C. Range 10 nA – 200 ìA in 1, 2, 5 steps Filter (cut off) Advanced Digital Filter, 0.5 - 0.001 Hz, 1, 2, 5 steps Pulse times t1: 100 - 2000 ms; t2: 0 - 2000 ms; t3: 0 - 2000 ms in 10 ms steps Sample times 20, 40, 60, 80 and 100 ms Range 10 nA – 200 ìA in 1, 2, 5 steps Scan rate 1 - 50 mV/s in 1, 2, 5 steps Cycle half, full or continuous DC mode (5 files) and pulse mode (4 files), cycle time, number of cycles and oven temperature. Time-based control of 50 time points as to range, filter, output contacts (2 TTL, 2 relays), auto zero, board id, offset, valve position (if present) and cell potential. Mains, Output, 2 Connectors 15 pins (A, B), manual valve (C), RS232C connector Dimensions 44 (D) x 22 (W) x 44 (H) cm = 17.3” (D) x 8.7” (W) x 17.3” (H) Weight 14.6 kg (32 lbs) without flow cell and column Power 100-240 VAC, 50/60 Hz, 260 VA max., auto-sensing Operating modes DC, PAD and Scan Potential range between +2.00 and -2.00 V in 10 mV increments Output between +1 and -1 V or between +10 and -10 V (20 bit D/A converter) Offset between +50% and -50% of max. output voltage, 5% steps Event marker pulse of 10% of max. output Auto zero triggered by keyboard, rear panel TTL, or RS232C control RS232C full parametric instrument control, data acquisition at 1, 2, 5 and 10 Hz Injector sensor starts system clock at injection Oven height 37 cm, from 7°C above ambient to 45°C, accuracy 0.5°C, stability 0.1°C; accommodates column and flow cell(s) Diagnostics LCD screen, keyboard and noise (internal dummy cell) Service mode system settings and calibration parameters Configuration menu for system customisation and optimisation Firmware upgradeable via PC (RS232), flash technology Environmental operating temperature: 4 – 40°C, RH 20 to 80%, non-condensing Physical specifications Specifications DECADE II General specifications DC mode PULSE mode SCAN mode AUTO mode Rear panel I/O connections

pageCatalog pdf di En 2012-02-06-10