Safety Isolation System - 20 Pages

Safety Isolation System
ElectroGuard™
Combination Systems with Thermal-magnetic Circuit Breaker/Optional Features Product Selection for Outside of North America (see page 12-19 for Ordering Instructions] ♦ Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below
Example: Catalogue Nuttier 2033- ♦0085H®-44K becomes Catalogue Number 2033-E0085H®-44K for "600A line Side hearing Bus and OutgoingRveer Cables" bussng designation.
Type of Bussing O
Catalogue Number Code
600A Line Side Incoming Bus and O utgoing Power Cables
E
1200A Line Side Incoming Bus and O utgoing Power Cables
D
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
H
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
R
<g> Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below
Example: Catalogue Nutter2033-C0085W®-48K becomes Catalogue Number 2033-C0085WN-48K for a 380V50Hz Input Line Voltage application
Input Line Voltage
220V 50Hz
380-400V 50Hz
400-415V 50Hz
440V 50Hz
500V 50Hz
550V 50Hz
Voltage Code for Catalogue N umber
A
N
G
B
M
C
Product Selection: Remote Lockout Station ©
Catalogue Number
"System Isolated" Light Colour
IP 30 Enclosure
IP 54 Enclosure
IP 65 Enclosure
Green
2030-RLSPG
2030-RLSHG
2030-RLSW G
Optional Features
Pneumatic Isolation Module (Must be ordered with Safety Isolation System):
The Safety Isolation System is available with an optional means of isolating the pneumatic energy source for the machine or process. If the machine operator/maintenance personnel initiates isolation of the electrical energy by operating one of the Remote Lockout Stations, a safety valve is simultaneously actuated to bleed pressure from the air line between the valve and the machine. When the air pressure has fallen to a predetermined level, the unit will allow the light on the Remote Lockout Station to illuminate, if electrical isolation has also been achieved.
To order the Pneumatic Isolation option:
Step 1: Add the folowiig Catalogue String to the Safety Isolation System Catalogue Number:
To indicate that the Safety Isolation System should be supplied as "Pneumatic Ready"
-1PN
eg 2031-A0085.B- 1PN to indicate an 85A Safstylsdation System that is to be "Pneumatic Ffeady" Step 2: Order sUtabyenclosed Rieunatc Isolation ModUe as separate item: For North America:
Pressure
Range
Valve Port Size
Catalogue Number
Type 1 General Purpose Enclosure
Type 12 Dust tight Enclosure
Type 4 Watertight Painted Steel Enclosure
Type 4X Watertight Stainless Steel Enclosure
30-120 ps
1in
2030-PA1201
2030-PJ1201
2030-PF1201
2030-PC1201
3/4in
2030-PA1203
2030-PJ1203
2030-PF1203
2030-PC1203
For Outside of North America:
Pressure Range
Catalogue Number
Valve Port Size
IP 30 Enclosure
IP 54 Enclosure
IP 65 Enclosure
2-7
bar
1in
2030-PP0071
2030-PH0071
2030-PW0071
3/4in
2030-PP0073
2030-PH0073
2030-PW0073
O Bus Type: Copper with tin plating Consult factory tor other types of bussing
© Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS If additional RLSare required, order the optional Expanson Module(s) (see page 12-16).
12-15
# Alien-Bradley
Safety Isolation System
  1. P. 1

  2. P. 10

    Safety Isolation System ElectroGuard Combination Systems with Thermal-magnetic Circuit BreakerProduct Selection for North America (see page 12-19 for...
  3. P. 11

    Safety Isolation System ElectroGuard Combination Systems with Thermal-magnetic Circuit BreakerProduct Selection for North America (see page 12-19 for...
  4. P. 12

    Safety Isolation System ElectroGuard™ Combination Systems with Thermal-magnetic Circuit Breaker ♦ Bussing Designation The Catalogue...
  5. P. 13

    Safety Isolation System ElectroGuard Combination Systems with Thermal-magnetic Circuit BreakerProduct Selection for Outside of North America (see page...
  6. P. 14

    Safety Isolation System ElectroGuard Combination Systems with Thermal-magnetic Circuit BreakerProduct Selection for Outside of North America (see page...
  7. P. 15

  8. P. 16

    Safety Isolation System ElectroGuard™ Optional Features (continued) Expansion Module (Can be ordered separately): For applications...
  9. P. 17

    Safety Isolation System ElectroGuard Optional Features (continued) Status Communication to a remote PLC (Should be ordered with Safety Isolation...
  10. P. 18

    Safety Isolation System ElectroGuard Typical Wiring Diagram/Wire Length ConsiderationsTypical Wiring DiagramWire Length Considerations Total Wire...
  11. P. 19

    Safety Isolation System ElectroGuard Wire Length Considerations/Ordering Instructions The total wire length for the 5 RLS to be wired to the Control...
  12. P. 20

    Safety Isolation System > Notes 12-20 >
Text version

All Allen Bradley catalogues and technical brochures

  1. Operator Interface

    54 Pages

    En
  2. RFID

    20 Pages

    En
  3. DeviceNet Sensors

    18 Pages

    En
  4. Network Media

    14 Pages

    En
  5. Connection Systems

    46 Pages

    En
  6. Encoders

    56 Pages

    En
  7. Ultrasonic Sensors

    16 Pages

    En
  8. Limit Switches

    143 Pages

    En
  9. Safety Switches

    160 Pages

    En
  10. Lighting Control

    26 Pages

    En
  11. Push Buttons

    226 Pages

    En

Archived catalogues

  1. Motors

    256 Pages

    En