Open the catalog to page 1Save TimeFixing Errors Save Layout Time Save Design Time > After specifying all units, CenterONEcan automatically lay out your MCC. Rearranging units is a simple drag-and- drop operation. Specifying the MCC ismade simple with selection menus forunits and sections. Save Mechanical Drafting Time > CenterONE generates AutoCAD Ι drawingsfrom your design. MCC elevation drawingis completed in minutes instead of hours. MCC Unit Wiring Diagram Save Electrical Drafting Time Save Quotation Time > CenterONE generates MCC one-lineӔ diagrams and unit diagrams directly from your design. Once your design...
Open the catalog to page 3Table of Contents General Information 1 Vertical Sections 2 Units 3 Contactor and Starter Units 4 Metering Units 5 Main and Feeder Units 6 Lighting and Power Panel Units 7 Transformer Units 8 Miscellaneous Units 9 Factory-Installed Options, Modifications, Accessories for Contactors and Starters, Metering, Mains and Feeders, Lighting and Power Panels, Transformer, and Miscellaneous Units 10 Combination Solid-State Controller (SMC) Units 11 Factory-Installed Options, Modifications, Accessories for Combination Solid-State Controller (SMC) Units 12 Variable Frequency AC Motor Drive Units 13...
Open the catalog to page 52100-2.0 Recommended General Specifications NEMA Type 1: 2100-2.0.1 CENTERLINE MCC Specification Checklist > Type 1 units and sections are intended for indoor use, primarily to provide a degree of protection against contact with the enclosed equipment in locations where unusual service conditions do not exist. The enclosures are designed to meet the rod entry and rust resistance design tests. The enclosure is sheet steel, treated to resist corrosion. 2400-2.0.1 IEC Specification Checklist 2100-4.2 Mains and Incoming Lines Dimension 2100-5.0 Bulletin 2100/2400 User Manual 2100-6.0.2 Renewal...
Open the catalog to page 8?From 1980 to 1996, only numbers 600000 to 999999 were used.?Refer to Series Identification for the implementation date of series letters on sections and units.?The serial numbers of sections are on the serial plate on the wireway door. On special width sections, the nameplate is located on the section door. ?The serial numbers of units are on the nameplate on the bottom of the units.?SCI sections or units will have a series letter after the unit or section catalog number.?In late 1995, some SC, SC-II, and PE orders were entered on PASSPORT. Bulletin 2100 Year Factory Order No. Serial...
Open the catalog to page 10This table gives a brief explanation of the series letter changes that have taken place since the original design of the CENTERLINE Motor Control Center. Complete new series units with comparable features and options can be retrofitted into any series of structures as shown in the table on page 7. Sections SeriesLetter Scope Description of Change Date Implemented in U.S. A > [1] [1] AllChanged terminal blocksNovember 1976C > [1] AllElimination of external mounting channelsJune 1979D > [1] AllReverse fed 2192 and 2193April 1981E > [1] AllRedesign gasketingOctober 1982F > [1] AllModified top...
Open the catalog to page 11This table gives a brief explanation of the series letter changes that have taken place since the original design of the CENTERLINE motor control center. Complete new series units with comparable features and options can be retrofitted into any series of structures as shown in the table on page 7. Units SeriesLetter Scope Description of Change Date Implemented in U.S. A > [1] [1] All sizesChanged terminal blocksNovember 1976C > [1] All sizesChanged handle mechanism to Cutler-Hammer/Westinghouse MCPsJune 1979D > [1] Size 5Changed from ITE to A-B 400A disconnectApril 1981E > [1] All...
Open the catalog to page 12?Maximum SC shipping block is three (3) vertical sections.?End closing plates are supplied on each of the shipping blocks containing incoming line or main breaker sections. Position and Description CatalogNumberCharacter Description DeliveryProgram A 42kA bus bar bracing SC B 65kA bus bar bracing SECOND C 42kA bus bar bracing with automatic shutters Bus Bar Bracing D 65kA bus bar bracing with automatic shutters E 42kA bus bar bracing with manual shutters F 65kA bus bar bracing with manual shutters AT06 600A aluminum bus with tin plating > [1] BT06 600A aluminum bus with tin plating and...
Open the catalog to page 18?Maximum SC shipping block is three (3) vertical sections.? End closing plates are supplied on each of the shipping blocks containing incoming line or main breaker sections. Ninth positioncontinued from previous page. Catalog NumberCharacter Position andDescription SpaceFactorsUsed Bottom Entry Description DeliveryProgram Top Entry AH A AJ A 225AJD#4-350 kcmil, 1/phaseCU1.5 SC AH B AJ B 225AHJD#4-350 kcmil, 1/phaseCU1.5 AH C AJ C 225AJDC#4-350 kcmil, 1/phaseCU1.5 AH D AJ D 400AKD#3/0-250 kcmil, 2/phaseCU2.0 Main Circuit Breaker SectionA AH E AJ E 400AHKD#3/0-250 kcmil, 2/phaseCU2.0 AH F AJ...
Open the catalog to page 20?Maximum SC shipping block is one (1) vertical section.? End closing plates are supplied.?Splice kits are not included .?Enclosures without horizontal bus are UL listed under the UL Standard for Safety UL 508 unless otherwise indicated. WorkingDepth(Inches) Section NEMA Type 1 NEMA Type 12 Description Depth (Inches) Width (Inches) CatalogNumber CatalogNumber DeliveryProgram 2100-EKC1_1D-_ _ > [1] 2100-EJC1_1D-_ _ > [1] 2100-EKC1_2D-_ _ > [1] 2100-EJC1_2D-_ _ > [1] 30 2100-EKC1_3D-_ _ > [1] 2100-EJC1_3D-_ _ > [1] 35 2100-EKC1_4D-_ _ > [1] 2100-EJC1_4D-_ _ > [1] 2100-EKC2_1D-_ _ > [1]...
Open the catalog to page 22?Maximum SC shipping block is one (1) vertical section.? End closing plates are supplied.?Splice kits are not included .?Enclosures without horizontal bus are UL listed to the UL Standard for Safety UL 508 unless otherwise indicated, short circuit withstand rating marking do not apply.?Line side of disconnect is connected to horizontal bus for sections with horizontal bus. > ? Customer cables connect to line side of disconnect for sections without horizontal bus > . Section Disconnect Rating (Amperes) NEMA Type 1 NEMA Type 12 > Description Working Depth(Inches) Depth (Inches) Width (Inches)...
Open the catalog to page 24All Allen Bradley catalogs and technical brochures
-
SENSOR-BR001
9 Pages
-
IA-BR005
64 Pages
-
937-SG001
70 Pages
-
937-PP001
4 Pages
-
931-TD001
52 Pages
-
931-AT001
2 Pages
-
931-AT002
4 Pages
-
Disconnect Switches
7 Pages
-
Encompass Partner - Stahlin
4 Pages
-
Encompass Partner - WIN-911
4 Pages
-
2014 Encompass Product
19 Pages
-
Essential Components
358 Pages
-
Operator Interface
54 Pages
-
RFID
20 Pages
-
DeviceNet Sensors
18 Pages
-
Network Media
14 Pages
-
Connection Systems
46 Pages
-
Encoders
56 Pages
-
Capacitive Proximity Sensors
22 Pages
-
Ultrasonic Sensors
16 Pages
-
Inductive Proximity Sensors
233 Pages
-
Photoelectric Sensors
334 Pages
-
Limit Switches
143 Pages
-
Safety Switches
160 Pages
-
Lighting Control
26 Pages
-
Push Buttons
226 Pages
-
Motor control centers
262 Pages
Archived catalogs
-
Motors
256 Pages
-
Motor Control Centers
42 Pages
-
Safety Isolation System
20 Pages
-
Applied Safety Solutions
10 Pages