Vertical Sections 2

CENTERLINE® Motor Control Centers - 5071 Catalog Number Explanation for Vertical Sections (SC)

?Maximum SC shipping block is three (3) vertical sections.? End closing plates are supplied on each of the shipping blocks containing incoming line or main breaker sections. Ninth position—continued from previous page. Catalog NumberCharacter Position andDescription SpaceFactorsUsed Bottom Entry Description DeliveryProgram Top Entry AH A AJ A 225AJD#4-350 kcmil, 1/phaseCU1.5 SC AH B AJ B 225AHJD#4-350 kcmil, 1/phaseCU1.5 AH C AJ C 225AJDC#4-350 kcmil, 1/phaseCU1.5 AH D AJ D 400AKD#3/0-250 kcmil, 2/phaseCU2.0 Main Circuit Breaker SectionA AH E AJ E 400AHKD#3/0-250 kcmil, 2/phaseCU2.0 AH F AJ F 400AKDC#3/0-250 kcmil, 2/phaseCU2.0 A J _(bottom entry)See page 235 for circuit breaker interrupting capacity or H _(top entry) AH G AJ G 600ALD250-350 kcmil, 2/phaseCU2.0 AH H AJ H 600AHLD250-350 kcmil, 2/phaseCU2.0 AH J AJ J 600ALDC250-350 kcmil, 2/phaseCU2.0 AH K AJ K 800AMDL#3/0-300 kcmil, 3/phaseCU2.5 AH L AJ L 800AMDLG#3/0-300 kcmil, 3/phase,CU with ground fault2.5 AH M AJ M 800AHMDL#3/0-300 kcmil, 3/phaseCU2.5 NINTHSection Location and Type AH N AJ N 800AHMDLG#3/0-300 kcmil, 3/phase,CUwith ground fault2.5 AH P AJ P 1200AND#4/0-400 kcmil, 4/phaseCU3.5 AH Q AJ Q 1200AHND#4/0-400 kcmil, 4/phaseCU3.5 AH R AJ R 1200ANDG#4/0-400 kcmil, 4/phase, CUwith ground fault3.5 AH S AJ S 1200AHNDG#4/0-400 kcmil, 4/phase,CUwith ground fault3.5Feeder Circuit Breaker SectionA AK D AL D 400AKD#3/0-250 kcmil, 2/phaseCU2.0 AK E AL E 400AHKD#3/0-250 kcmil, 2/phaseCU2.0 A L _(bottom entry)See page 235 for circuit breaker interrupting capacity AK F AL F 400AKDC#3/0-250 kcmil, 2/phaseCU2.0 or K _(top entry) AK G AL G 600ALD250-350 kcmil, 2/phaseCU2.0 AK H AL H 600AHLD250-350 kcmil, 2/phaseCU2.0 AK J AL J 600ALDC250-350 kcmil, 2/phaseCU2.0 AK K AL K 800AMDL#3/0-300 kcmil, 3/phaseCU2.5 AK M AL M 800AHMDL#3/0-300 kcmil, 3/phaseCU2.5 AK P AL P 1200AND#4/0-400 kcmil, 4/phaseCU3.5 AK Q AL Q 1200AHND#4/0-400 kcmil, 4/phaseCU3.5 NINTH POSITION(Continued on next page)

14


pageCatalog pdf di En 2012-05-21-26