UPM6100 - Portable Power measuring device

6 UPM6100 Connection Panel

Current inputs

The instrument can process measurements from current vices or other transducers with 1, 2, 3 or 10V full scale outputs. Inputs are not isolated; it is always necessary to connect

Auxiliary power feeder Fuse Voltage inputs

85 - 250 V
AC or 90 - 250 V
DC Instrument power supplycircuit protection. Direct connection up to 600V
AC (750).Above this value the use of voltage transformers is necessary. VT ratio's can be programmed. Voltage interruptions longer than20-30msec are detected and printed with a resolution of 0,1 s. transducers with double insulation accordingEN61010-1 safety standard.Flexible Rogowski transducers can be directlyconnected to the inputs without adaptors. The programmable full professional scales are 700 and 3000A.

Earth leakage input

A dedicated input, for measurement of earth leakage current by 0-1V clamps or directly from 1000 turns split-core CT.

Inputs for direct connection

Isolated inputs for direct connection of voltages up to 600(750)V L-L. Maximum current 20 (25)A RMS.These inputs can be programmed for use withtransducers with 1 and 5A output value (clamps or current transformers).

Analog output (option) Digital inputs (option) Serial interface RS232 Temperature sensor supplier Digital output (option)

No. 1 optoisolated active outputthat can drive the load with no need for an external power supply.It can be programmed as 0-20 or4-20mA and associated to one of the main instantaneous values. No. 4 isolated inputs for voltage-free contacts. Can be used for energy pulses counting, demand syncronization or status indication (according to installed options). The UPM6100 is provided withserial communication port RS232 to connect to a PC, modem or Industrial ethernet gateway. Detects and displays theenvironmental temperature. No. 1 optoisolated output that can be programmed for energy pulse emission or alarm.

Printouts Examples

Size mm

210 210

420 420 340 340 Graphic printout of fivevariables (V, A, kW, kvar,f).Automatic printout witha time interval of 10". Print screen of numericaland graphic pagesPrintout of the daily 15'power demand histogramat midnight.