ALMEMOŽ MEASURING INSTRUMENTS ALMEMOŽ 2690-8 - AHLBORN - #1

/ 3


catalogue search
ALMEMOŽ MEASURING INSTRUMENTS ALMEMOŽ 2690-8 - AHLBORN
P. 01
ALMEMOŽ MEASURING INSTRUMENTS ALMEMOŽ 2690-8 - AHLBORN
P. 02
ALMEMOŽ MEASURING INSTRUMENTS ALMEMOŽ 2690-8 - AHLBORN
P. 03
Pages:
ALMEMO® MEASURING INSTRUMENTS ALMEMO® 2690-8 - AHLBORN


See other catalogues for AHLBORN

Text version of the page
ALMEMOŽ MEASURING INSTRUMENTS 01.18 10/2008 We reserve the right to make technical changes. 01 www.ahlborn.com Technical data Measuring inputs: 5 ALMEMOŽ input sockets, electr. isol., with semiconductor relay (50 V) Channels 5 primary chann., maximum 19 additional chann. for double sensors and function chann. (e.g. differential values) A/D converter Delta-sigma 24-bit, 50 meas. op. p. s. see Technical data, page 01.05 Sensor power supply Battery 6 / 9 / 12 V, maximum 100 mA Mains adapter 12 V, maximum 100 mA Outputs 2 ALMEMOŽ sockets for all output modules (analog, data, trigger, relay cables, memory etc.) Standard equipment Display Graphics, 128x128 pixels, 16 rows Lighting, 5 white LEDs, 3 levels Keypad 9 tactile silicone keys (4 soft-keys) Memory 512-KB EEPROM (100,000 meas. values) Date and time-of-day Real-time clock, buffered with battery Power supply Battery 3 AA alkaline batt. or rechargeable batt. Mains adapter ZA1312NA7, 230 V AC to 12 V DC, 1000 mA, electrically isolated DC adapter cable, electrically isolated ZA2690-UK, 10 to 30 V, 0.25 A Current consumption without input and output modules Active mode approx. 30 mA with lighting approx. 50 to 150 mA SLEEP mode approx. 0.05 mA Housing (LxWxH) 209 x 107 x 54 mm ABS (maximum 70 °C), 570 g Protection IP54 if splash-proof connectors / sensors are used Included as standard Extent of the delivery Order no. Data logger ALMEMOŽ 2690-8, Operating instructions, ALMEMOŽ Manual, including manufacturer’s test certificate, AMR-Control software MA26908 Data logger set ALMEMOŽ 2690-8 in case, as above including mains adapter and data cable in case MA26908KS Option KL (see pages 01.17 and 03.03) Multi-point calibration, special ranges OA2690KL Option R (see page 11.08) Temperature ranges for 8 coolants SB0000R2 Option Q4 : 400 mops measuring rate (see 01.05) SA0000Q4 Top hat rail mounting OA2290HS Accessories Mains adapter 12 V / 1000 mA ZA1312NA7 Rechargeable battery set with 3 NiMH AA cells 1600 mAh, coded, and adapter for high-speed charging, maximum 2 A ZA2690AS DC adapter cable, 10 to 30 V DC, 12 V / 0.25 A, electr. isol. ZA2690UK Memory connector with MMC card, including USB card reader (see p. 04.07) ZA1904MMC Analog output cable, -1.25 to 2.0 V, 0.1 mV / digit ZA1601RK Trigger and alarm cable (2 relays, 1 ohm, 300 mA, 50 V) ZA1000EGK V24 data cable, electr. isol., max. 115.2 KB ZA1909DK5 Ethernet data cable, electr. isol., max. 115.2 KB ZA1945DK Transport case, large (aluminum), see Chapter 07 ZB2590TK2 Network technology, Bluetooth modules, see Chapter 05 Other general data see Technical Data, page 01.05 ALMEMOŽ 2690-8 Multi functionally measuring instrument and data logger with 5 measuring inputs, 2 outputs, RS232, Ethernet, analog Technical features .. Modern housing with rubberized impact protection and positioning clip; also moisture-proof thanks to new, injectionmolded connectors and sealing lips. .. 5 ALMEMOŽ input sockets, electrically isolated, for 5 ALMEMOŽ sensors, 20 sensor chann., 4 additional internal function chann. .. 2 ALMEMOŽ output sockets for digital interfaces, analog output, trigger input, alarm contacts, memory card. .. High-speed, high-resolution A/D converter, 24-bit, 50 meas. op. per sec. New measuring ranges Pt100, 0.000 to 65.000 °C. .. Ideal display with large, brightly illuminated graphics. .. Easy and convenient operation by means of 4 soft-keys and cursor block, Comprehensive menu system with wizards and help windows. .. 9 measuring menus (3 can be freely configured by user from range of 50 functions). .. Measured values can be displayed graphically in line diagram or bar chart form and from 1 to 20 measured values can be displayed numerically in various sizes. .. Measuring functions : Measured value, zero-setting, setpoint adjustment, maximum and minimum values stored with date and time-of-day, smoothing, average values over time or measuring points, limit value monitoring, cold junction compensation, temperature compensation, and atmospheric pressure compensation. .. 8 programming menus for easy-to-understand parametrization of cycles, times, memory, output modules, and power supply Sensor programming with range, units, comments, scaling, error correction, etc. .. Option KL : Multi-point calibration, calibration data management, user-defined linearization, special ranges in the ALMEMOŽ connector, e.g. 0.000 to 50.000 ohms, NTC -5.000 to 46.000 °C, YSI 400. .. 10 wizards for quickly and easily mastering otherwise complex configurations : Sensor scaling, two-point adjustment, calculation functions, and reference channels; Sensor programming for determining thermal coefficients and wet-bulb globe temperature (WBGT), alarm relay assignment, scaling, and analog output assignment. .. Choice of languages : German, English, French. .. EEPROM with capacity for 100,000 measured values, internally configurable as linear or ring memory. .. Memory connector with MMC card and standard file format. .. SLEEP mode for long-term recording. .. Device software update via interface.

pageCatalog pdf di En 2012-05-20-14