Gas Chromatograph % , ppm and ppb analysis using a Flame Ionisation Detector Features The new NovaCHROM 3000 GC contains the latest GC technology based around the industry proven Flame Ionisation Detector (FID). The state of the art technology is a result of 50 years of experience that makes AGC Instruments a leading manufacturer in the industry. This rugged detector design, of which AGC Instruments has extensive experience, is ideal for both cost effective and reliable gas analysis. Utilising the latest advanced technologies, this GC provides customers with the precise results they require with the ease of use and support features expected. The NovaCHROM 3000 GC uses the industry proven Flame Ionisation Detector (FID) for the measurement of Hydrocarbons in a various gas streams. This detector will allow measurements from % down to ultra low ppb levels with ease and with minimal training required. Using the new interactive touch screen, the NovaCHROM series is easy to use and set-up. The arrival of the new Electronic Pressure & Flow Management System has ensured all functionality is easy and accessible also. The constant monitoring of critical status information such as flows, pressures and temperatures is readily available to the operator and is backed up with the Alarm activation which allows feedback locally to other locations such as the Control Room or DCS. This information allows all personnel to know that the GC is performing to specification with the peace of mind that goes with it. Therefore the NovaCHROM 3000 provides a top class performance to you at all times. The AGC Engineering Team will custom design an analytical solution to meet your application. All systems are designed with pipework not exceeding 1/8” in diameter and using only Swagelok® stainless steel fittings, the flow paths are contamination free and allows a fresh sample to reach the detector with speed. Coupled with the world famous Vici Valco® Rotary Valves, the robust systems ensure an excellent stability, sensitivity and a long working life. Furthermore, AGC are renowned for After Sales Service which is available locally in each market. The expertise is available to you at all times so that your ownership of the system is always supported. Flame Ionisation Detector (FID) Electronic Pressure & Flow Management System Accuracy to ±0.5% Full Scale Fast Detector Response: < 0.5 seconds (90%) Ideal for analysis of Hydrocarbons Versatile & Robust Detector design Cost Effective and Reliable Large Colour 6.5” LCD Touch Screen Long Term Stability & Sensitivity Electropolished Stainless Steel Tubing Integrated Configurable Alarms System Packed, Micro-Packed & Capillary Columns for Maximum Sensitivity Independent Column Ovens with individual Temperature Control Integrated Diagnostics System Full Control by TrendVision PLUS Software Increased Connectivity with both USB, RS-232 and RS-485 Drop Down Front Panel for easy access during maintenance and servicing

Open the catalog to page 1
NovaCHROM 3000 GC - 2

Principle Of Operation The AGC NovaCHROM 3000, using the Flame Ionisation Detector (FID), is used to measure concentrations of hydrocarbons within a sampled gas. The presence of hydrocarbons is detected by burning the sampled gas in an air-hydrogen flame. Burning just pure hydrogen with air produces only trace amounts of ionisation. The presence of hydrocarbons in the sampled gas, when burnt with an air-hydrogen mix causes high levels of ionisation. The ionisation occurs a result of the carbon atoms present in the sampled gas. The level of ionisation is proportional to the number of carbon...

Open the catalog to page 2
NovaCHROM 3000 GC - 3

Specification Detector Flame Ionisation Detector (FID) Temperature Range Detector Response Time 10 μV maximum, depending on operating parameters 19” Rack, Bench Top or Wall Mount 6.5” LCD Colour Display with LED backlight and resistive touch screen Nitrogen (N2), Helium (He), Argon (Ar) : <5ppm H2O free from CnHm 20-40mL/min Support Gases 10 - 500 mL/min flow (200ml/min flow recommended) 5-10 Bar input: Controls Carrier Gas Output from 0-5 bar Vici Valco® high purity rotary valves Standard Fittings 1/8” Stainless Steel with Swagelok® fittings Output Signal** Packed, Micro-Packed and...

Open the catalog to page 3
NovaCHROM 3000 GC - 4

Company Profile AGC Instruments AGC Instruments is a leading manufacturer of Gas Analysis Solutions to all users requiring a Quality Control or identification of their gas stream. We have over 50 years experience in providing our customers with their “Total Gas Analysis Solutions”. We work closely with all customers to ensure they obtain the analytical solution that meets their needs and a system that is easy to use and understand. All AGC distributors are extremely experienced and factory trained to the highest standards, offering you a complete after sales support service. The wide range...