You may also be interested in
Extractor hood, Fume extractor, Extraction system, Panel, Centrifugal fan
Text version of the page
116
AERSERVICE FORNISCE PRODOTTI E SOLUZIONI TENENDO CONTO
DI RIFERIMENTI NORMATIVI NAZIONALI E INTERNAZIONALI
WELDING AND FINISHING AREA 1
APPLICATIONS
The AER series of portable air cleaners are particularly suitable for easy transportation and use in the aspiration of
welding fumes in intermittent work processes or on construction sites to safeguard the health and safety of the operator,
especially in enclosed or poorly ventilated locations (e.g. tanks, shelters, etc.) in which the clean air would otherwise be
rapidly saturated by pollutants.
These units are also associated with a specific application for continuous service when used in conjunction with wire
welding systems utilised a torch equipped with a suction function, in which they are able to treat the fumes directly at
source simultaneously with the welding process. In this case model AER 102 can be further refined by equipping the
SUCTION fan with an automatic start/stop device operating in conjunction with the welding torch.
AERSERVICE SUPPLIES PRODUCTS AND SOLUTIONS TAKING ACCOUNT
OF NATIONAL AND INTERNATIONAL NORMATIVE REFERENCES
OPERATOR SAFETY
Pollutants deriving from industrial and small
workshop processes must be captured as
close as possible to the point of release and
routed to the exterior of the workplace. In
the case of intermittent work processes
however, such pollutants can be aspirated
and filtered out of the air, which is subsequently
returned to the workplace. In this
case, in addition to the use of portable air
cleaner systems the installation of ambient
ventilation systems may be required. Italian
decree D.Lgs. 81/2008 - 2006/15/EC
TECHNOLOGY EMPLOYED
To guarantee and satisfy the applicable
national and international standards
and regulations, we make use of the
best available technology, which, combined
with superior technical know-how,
results in the creation of safe products
that are in compliance with the people
responsible for using the equipment;
for example, the speed of capture of
the pollutant is never considered at
less than 0.5 m/sec during the design
stage (as required by the controlling
authorities).
ENVIRONMENTAL ASPECT
The filtration performance levels guaranteed
are established in accordance
with international specifications that
limit the concentration levels of airborne
pollutants for professional activities
for which a repeatedly exposed worker
does not suffer any form of health
impairment. American Conference of
Industrial Hygienists (ACGIH) – Italian
decree D.M. 20/08/1999. National
and international regulations are referred
to the values specified by ACGIH.
|
|