You may also be interested in
Electrical tester, Software, RF combiner, Radio test set, Protocol analyzer
Text version of the page
For the very latest specifications visit www.aeroflex.com
L3/NAS FEATURES (OPTIONAL)
Protocol layers
RRC, BMC, PDCP & NAS
USIM/UICC
Supported via external UICC card reader
Services
Support of circuit-switched voice and data services. Support of packetswitched
data services
Handover support
Softer, soft and hard handover
UE Service capabilities (via NAS)
Emergency call, SMS, cell broadcast, supplementary services
MEASUREMENTS AND STATISTICS
HSDPA L1 measurements
HS-SCCH detection and parameter information, HS-DSCH decode
statistics, HS-DPCCH information
R99 L1 measurements
Support of 25.215 measurements, plus detailed cell search and
dedicated channel information
Layer 2
MAC and RLC transmission and reception measurements, frame
throughput and statistics
TEST FUNCTIONS
Open interface
Scripted control of the TM500 at L1
Variable parameters
Power control, channel coding, UL transport channel data, transmitted
channel power, number and power of RACH preambles, control over
key timers, expiry times and more
USER INTERFACE
Mobile Data Logger (MDL)
Graphical application for the control of the TM500 and display of
logged data
L1 Script Editor (LISE)
Graphical application for creating and editing TM500 control scripts
Protocol logging tool (PCO+)
Application for the control of SAPs used to observe and display logged
data in a message sequence chart. Filters can be applied to aid
analysis and debugging. Provided with L3/NAS option
Phone application
Provides graphical phone dialler and windows for SMS, PDCP,
supplementary services and scripted control. Provided with L3/NAS
option
Protocol Manipulation and Interaction (PMI)
Optional protocol extensions tool to enable thorough and repeatable
testing and analysis
Includes support for generating error scenarios and forced/rogue
behavior
AMR CODEC
Internally fitted AMR codec
Supports 12.20kbps, 10.20kbps, 7.95kbps, 7.40kbps, 6.70kbps,
5.90kbps, 5.15kbps, 4.75kbps
RF
Transmit
1920 MHz – 1980 MHz
Receive
2110 MHz – 2170 MHz
Duplex
Variable duplex
Power class
3 (+24 dBm)
SAFETY & EMC
Low Voltage Directive
73/23/EEC as amended by 93/68/EEC
Electromagnetic Compatibility Directive
89/336/EEC as amended by 92/31/EEC & 93/68/EEC
DIMENSIONS
Height x width x depth
310mm x 480mm x 460mm
ENVIRONMENTAL
Weight
18 kgs
Operational temperature
0°C to 45°C
Storage temperature
-40°C to 70°C
Vibration
IEC 68-2-6 and IEC 68-2-36
Bump and shock
IEC 68-2-27
Relative Humidity
10%-80% Non-condensing
Altitude
-200 m to 2000 m
POWER SUPPLY
AC input voltage range
100 – 250 V
AC frequency range
50 – 60 Hz
|
|