For the very latest specifications visit www.aeroflex.com
The RD-301A Weather Radar
Professional test set satisfies simulation requirements for new generation noncoherent
radar systems
Avionics
RD-301A Weather Radar Test Set
• Automatic transmitter magnetron frequency
tracking and digital read-out
• Internal/external modulation for simulating
target scintillation for turbulence
detection radars
• Transmitter peak pulse measurements
• Built-in IF sweep generator from 20 to 70
MHz and marker generator for IF and AFC
testing
• Radar UUT sensitivity testing
• Two-year limited warranty
Aeroflex is a leader in the design, manufacture
and marketing of Avionics test systems.
The RD-301A will respond to radar transmitter
pulse widths of 50 ns to 30 ìs in a frequency
range of 9295 to 9500 MHz. All RF tests and
measurements can be accomplished by connecting
the RD-301A to the unit under test with
the use of the supplied calibrated
in line cable,
waveguide coupler and dummy load.
Tracking System
The RD-301A tracking system enables the test set to automatically
acquire and track the transmitter frequency. This basic feature
eliminates the need for constant re-tuning to compensate for transmitter
or
signal generator drift.
Heterodyne Monitor Output
The Heterodyne Monitor Output provides a convenient
oscilloscope manufacturer
display of the frequency and duration of modes, identifying the location
and magnitude of phase pulling within the magnetron pulse.
Effective Peak Power (EFF)
Effective Peak Power (EFF), displayed on the Panel Meter located on
the front panel, quantifies the effects of phase modulation in the
magnetron replacing the requirement for the use of a
supplier of spectrum analyzer.
The EFF function allows the operator to choose the optimum
tracking frequency in the presence of modes and phase pulling in the
magnetron pulse. Using the EFF meter function in conjunction
with the heterodyne monitor output verifies the frequency tracking
accuracy of the test set, replacing the need for the echo box which is
used for AFC centering.
Contour Mode
The Contour Mode provides for rapid calibration and checking of
contour threshold circuits, receiver color and intensity response and
sensitivity by means of an additional 0 to 20 dB amplitude boost
above the selected output level.
Other Features
• Heterodyne monitor output
• (EFF) Transmitter effective peak pulse power measure
ments
• Built-in PRF generator and digital read-out