SPECIFICATION
DME MODE SPECIFICATIONS
SIGNAL GENERATOR
A 5-minute warm-up period is required for all specifications.
OUTPUT FREQUENCY
REPLY FREQUENCY
Range
962 to 1213 MHz
Accuracy
±10 kHz
OUTPUT LEVEL
ANTENNA PORT
Range
-67 to -2 dBm at Antenna port
Resolution
1 dB
Accuracy
±2 dB
Distance to UUT antenna
6 to 300 ft with supplied antenna
RF I/O PORT
Range
-115 to -47 dBm
Resolution
1 dB
Accuracy
-95 dBm to –47 dBm ±1 dB
Accuracy
-115 dBm to <-95 dBm ±2 dB
REPLY PULSE SPACING
P1 to P2
12 ěs (±100 ns) (X Channel) @ 50% peak
P1 to P2
30 ěs (±100 ns) (Y Channel) @ 50% peak
REPLY PULSE WIDTH
P1/P2
3.5 ěs (±0.5 ěs)
ECHO REPLY
Control
On/Off
Position
30 nmi (±1 nmi)
Amplitude
-11 dB (±1 dB) relative to reply level
REPLY PULSE RISE AND FALL TIMES
ALL PULSES
Rise Time
2.5 ěs (±0.25 ěs) (10% to 90%)
Fall Time
2.5 ěs (±0.25 ěs) (90% to 10%)
REPLY DELAY
X CHANNEL
Fixed Reply Delay
50 ěs (±100 ns)
Y CHANNEL
Fixed Reply Delay
56 ěs (±100 ns)
RANGE DELAY
X AND Y CHANNEL
Range
0 to 450.00 nmi
Resolution
0.01 nmi
Accuracy
±0.01 nmi
RANGE RATE
X AND Y CHANNEL
Range
10 to 6500 kts
Resolution
1 kts
Accuracy
±0.01% typical, tested to ±0.5%
SQUITTER
PRF
2700 Hz
Accuracy
±2%
Distribution
Per ARINC 568
|
|