For the very latest specifications visit www.aeroflex.com Gain 6 dB, Typical TIME BASE (TCXO) Temperature Stability ±1 ppm Aging ±1 ppm per year Accuracy ±1 ppm Test Limit ±0.3 ppm BATTERY Type Li Ion Duration >4 hrs continuous operation >6 hrs, Typical INPUT POWER (TEST SET) Input Range 11 to 32 Vdc Power Consumption 55 W Maximum 16 W Nominal at 18 Vdc with charged battery Fuse Requirements 5 A, 32 Vdc, Type F INPUT POWER (SUPPLIED EXTERNAL AC TO DC CONVERTER) Input Range 100 to 250 VAC, 1.5 A Max, 47 to 63 Hz Mains Supply Voltage Fluctuations 10% of the nominal voltage Transient Overvoltages According to Installation Category II ENVIRONMENTAL (TEST SET) Use Pollution Degree 2 Altitude 4800 meters Operating Temperature NOTE 2 -20°C to 55°C Storage Temperature NOTE 3 -30°C to 71°C Relative Humidity 95% (±5%) from 5° to 30°C 75% (±5%) from 30° to 40°C 45% (±5%) from 40° to 55°C ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC CONVERTER) Use Indoors Altitude 10,000 meters Operating Temperature 0° to 40°C Storage Temperature -20°C to 71°C PHYSICAL CHARACTERISTICS DIMENSIONS Height 11.2 inches (28.5 cm) Width 9.1 inches (23.1 cm) Depth 2.7 inches (6.9 cm) Weight (Test set only) <8 lbs. (3.6 kg) SUPPLEMENTAL INFORMATION Test Set Certifications Altitude, operating MIL-PRF-28800F Class 2 Altitude, not operating MIL-PRF-28800F Class 2 Bench Handling MIL-PRF-28800F Class 2 Blowing Dust MIL-STD-810F Method 510.4, Procedure I Drip-proof MIL-PRF-28800F Class 2 Explosive Atmosphere MIL-STD-810F Method 511.4, Procedure 1 Relative Humidity MIL-PRF-28800F Class 2 Shock, Functional MIL-PRF-28800F Class 2 Vibration Limits MIL-PRF-28800F Class 2 Temp, operating NOTE 4 MIL-PRF-28800F Class 2 Temp, not operating NOTE 5 MIL-PRF-28800F Class 2 Transit Drop MIL-PRF-28800F Class 2 Safety Compliance UL-61010B-1 EN 61010-1 CSA 22.2 No 61010-1 EMC EN 61326 External AC-DC Converter Certifications Safety Compliance UL 1950 DS CSA 22.2 No. 234 VDE EN 60 950 EMI/RFI Compliance FCC Docket 20780 Curve “B” EMC EN 61326 Transit Case Certifications Drop Test FED-STD-101C Method 5007.1 Paragraph 6.3, Procedure A, Level A Falling Dart Impact ATA 300 Category I Vibration, Loose Cargo FED-STD-101C Method 5019 Vibration, Sweep ATA 300 Category I Simulated Rainfall MIL-STD-810F Method 506.4 Procedure II of 4.1.2 FED-STD-101C Method 5009.1 Sec 6.7.1 Immersion MIL-STD-810F Method 512.4

pageCatalog pdf di En 2012-02-07-13