You may also be interested in
Signal analyzer, Test system, Tester, Synthesizer, Power meter
Text version of the page
For the very latest specifications visit www.aeroflex.com
Transient Over-voltages
According to installation category II
ENVIRONMENTAL (TEST SET)
Use
Pollution degree 2
Altitude
4800 meters
Operating Temperature (NOTE 3)
-20°C to 55°C
Storage Temperature (NOTE 4)
-30°C to 70°C
Relative Humidity
80% from 5°C to <10°C
95% from 10°C to <31°C
75% from 31°C to <40°C
45% from 40°C to 50°C
ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC CONVERTER)
Use
Indoors
Altitude
3,000 meters
Temperature
5°C to 40°C
PHYSICAL CHARACTERISTICS
Dimensions:
Height
11.2 in (28.5 cm)
Width
9.1 in (23.1 cm)
Depth
2.7 in (6.9 cm)
Weight (Test Set Only)
<8 lbs. (3.6 kg)
SUPPLEMENTAL INFORMATION
Audio distortion characteristics are measured in a 20 Hz to 15 kHz
post detection bandwidth.
All DDM measurements are made on RF output signal.
Test Set Certifications
Altitude, operating MIL-PRF-28800F Class 2
Altitude, not operating MIL-PRF-28800F Class 2
Bench Handling MIL-PRF-28800F Class 2
Blowing Dust MIL-STD-810F Method 510.4,
Procedure I
Drip-proof MIL-PRF-28800F Class 2
Explosive Atmosphere MIL-STD-810F Method 511.4,
Procedure 1
Relative Humidity MIL-PRF-28800F Class 2
Shock, Functional MIL-PRF-28800F Class 2
Vibration Limits MIL-PRF-28800F Class 2
Temp, operating NOTE 5 MIL-PRF-28800F Class 2
Temp, not operating NOTE 6 MIL-PRF-28800F Class 2
Transit Drop MIL-PRF-28800F Class 2
Safety Compliance UL-61010B-1
EN 61010-1
CSA 22.2 No 61010-1
EMC EN 61326
External AC-DC Converter Certifications
Safety Compliance UL 1950 DS
CSA 22.2 No. 234
VDE EN 60 950
EMI/RFI Compliance FCC Docket 20780 Curve “B”
EMC EN 61326
Transit Case Certifications
Drop Test FED-STD-101C Method 5007.1
Paragraph 6.3,
Procedure A,
Level A
Falling Dart Impact ATA 300 Category I
Vibration, Loose Cargo FED-STD-101C Method 5019
Vibration, Sweep ATA 300 Category I
Simulated Rainfall MIL-STD-810F Method 506.4
Procedure II of 4.1.2
FED-STD-101C Method 5009.1
Sec 6.7.1
Immersion MIL-STD-810F Method 512.4
|
|